5-43
ASSEMBLY
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
Dura+ User Manual
Power
Electric Plugs
T/C Electric
Plugs
Sub-Manifold
T/C Wires
Sub-Manifold
Power Wires
SUB-MANIFOLD
ELECTRICAL BOXES
SECURE IN
BRIDGE WIRE ARMOR
Female “xT” Quick
Connect Plug
Male “xT” Quick
Connect Plug
Female “xP” Quick
Connect Plug
Male “xP” Quick
Connect Plug
1. Run all the power wires to the bridge and locate a position for quick
connector sitting, and cut the wires to a proper length.
2. Label the wires and install high temperature sheathing.
3. Crimp all heater plates and nozzle power wires with female contacts.
4. Insert the power wires contacts into the male plug of quick connector ‘1P’
per wiring schematic in General Assembly drawing.
5. Insert the coding pin to the male plug as per wiring schematic, if
applicable.
6. Get six spare wires crimped with male contacts in one end, insert into the
female plug of quick connect ‘1P’, and label the wires according to the
male side.
7. Snap ‘1P’ plugs together. Run the open end of the wires to the electrical
plugs. Cut the wires to the proper length and crimp them. Install high
temperature sheathing if needed.
8. Install the power wires into electric plugs per wiring schematic in the
General Assembly drawing.
9. Repeat above for each zone. Name connector number according to drop
number. Be sure to locate the connectors inside the wire armor. See
“5.10.4 Wiring Channel” on page 5-41 for further details.
5.11 Sub-Manifold Wiring
CAUTION
All wires close to a heat source require high temperature sheathing.
CAUTION
5.11.1 Power Wiring