3. Check the bottom face of the nozzle counterbore for damage. If damaged,
lap the bottom face of the nozzle in a circular fashion with a hardened
tool and 300 grit lapping compound. If the nozzle counterbore is free of
damage, proceed to step 5.
4. After lapping is complete, apply die spotting blue to the liner to the nozzle
to ensure proper mating. If the liner is making good contact, clean the die
spotting blue compound off both faces.
5. Apply anti-seize compound (nickel based) to the gate seal threads ONLY.
Make sure that the internal runner is clean and free from anti-seize
compound.
6. Using a socket wrench, reinstall the gate seal being careful not to damage
it.
7. Torque the gate seal to the appropriate value. Refer to “Gate Seal Torque
8. Check that the seal has bottomed out, heat nozzle to process temperature
and re-torque seal.
Gate Seal Replacement - continued