24. Assemble the inlet tip into the heated body and torque to 68 Nm
(50 lbf-ft).
25. Attach the gate seal and liner to nozzle. Attach nozzle thermocouple.
26. Assemble the adapter into the nozzle.
27. Insert the screws. For M5 screws, torque to 7 Nm (5 lbf-ft). For M8 screws
torque to 20Nm (15 lbf-ft).
NOTE
Hecto nozzles do not need the screws to be installed in this procedure. Two
screws will be installed with the heated body.
DECI nozzles only
MEGA nozzles only