List of Figures
3.1. Example nameplate label found on back of a CT100B. . . . . . . . . . . . . . . . .
11
3.2. Diagram of the CT100B front panel. . . . . . . . . . . . . . . . . . . . . . . . . . .
12
3.3. Diagram of the rear panel of the CT100B/CT100HF. . . . . . . . . . . . . . . . . .
14
3.4. Screenshot showing typical features of the CT100B.
. . . . . . . . . . . . . . . . .
16
3.5. Clip lead adapter and controlled impedance adapter . . . . . . . . . . . . . . . . .
28
3.6. Screenshot showing AUTOFIT result. . . . . . . . . . . . . . . . . . . . . . . . . .
29
knob to improve Vp accuracy. . . . . . . . . . .
30
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
3.9. Smoothed vs. unsmoothed traces at very small vertical scales . . . . . . . . . . . .
31
3.10. A small fault in a long cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32
3.11. AUTOFIT cable. The cable termination is a short. . . . . . . . . . . . . . . . . . .
33
3.12. Vertical scale used to emphasize cable fault. . . . . . . . . . . . . . . . . . . . . . .
33
3.13. A zoomed in view of the cable fault . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
3.14. Relative distance measurement between two small impedance “faults” caused by
BNC connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
3.15. Multi-segment cable segment with Vp of 0.400 . . . . . . . . . . . . . . . . . . . . .
35
3.16. Multi-segment cable segment with Vp of 0.850 . . . . . . . . . . . . . . . . . . . . .
36
3.17. Scan progress display with Cancel button. . . . . . . . . . . . . . . . . . . . . . . .
36
3.18. Scan of a portion of a cable, zoomed-in vertically. . . . . . . . . . . . . . . . . . . .
37
3.19. Selecting the live trace.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
3.20. Selecting a scanned trace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38
3.21. Selecting a difference trace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
3.22. Using the on-screen keyboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40
3.24. A trace that passes the mask test . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42
3.25. A trace that fails the mask test . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42
3.26. Envelope Plot with Fill Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
45
3.27. Envelope Plot with Probability Density display. . . . . . . . . . . . . . . . . . . . .
45
3.28. Envelope Plot with Fill Mode, showing the range of impedance values . . . . . . .
46
3.29. Difference trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
46
3.30. First-derivative trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
47
3.31. Resistive cable loss correction, before.
. . . . . . . . . . . . . . . . . . . . . . . . .
49
3.32. Resistive cable loss correction, after. . . . . . . . . . . . . . . . . . . . . . . . . . .
49
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51
between cursors bracketing an SMA barrel adapter on the TDR trace. . . . . .
53
between cursors with tightened connector . . . . . . . . . . . . . . . . . . . . .
53
between cursors with loosened connector . . . . . . . . . . . . . . . . . . . . . .
54
3.37. Using a phase stable cable to improve S-parameter measurements . . . . . . . . . .
55
3.38. Smith chart representation of open fault . . . . . . . . . . . . . . . . . . . . . . . .
55
3.39. Smith chart representation of short fault . . . . . . . . . . . . . . . . . . . . . . . .
56
3.40. Smith chart representation of a 50 ohm resistive load . . . . . . . . . . . . . . . . .
56
3.41. Smith chart of reactive 200 ohm load . . . . . . . . . . . . . . . . . . . . . . . . . .
57
3.42. Normalized trace showing short fault in a 50 ohm cable. . . . . . . . . . . . . . . .
57
CT100B TDR Cable Analyzers Operator’s Manual