16
cut IN is Set Point Plus Differential (Hy). Compressor cut OUT is when the temperature reaches
the set point.
-
AC Anti-short cycle delay
: (0÷30 min) minimum interval between the compressor stop and the
following restart.
-
PAU Time of stand by:
(0 ÷ 60min) after this time the controller restart the cycle.
-
PFt Maximum acceptable duration of power failure:
(0 ÷ 250 min) if power failure duration is
less than PFt, the cycle restarts from the same point at which it was stopped otherwise the cycle
restarts from the beginning of the current phase.
-
Con Compressor ON time with faulty probe
: (0÷ 255 min) time during which the compressor is
active in case of faulty thermostat probe. With COn=0 compressor is always OFF
-
COF Compressor OFF time with faulty probe
: (0÷255 min) time during which the compressor
is off in case of faulty thermostat probe. With COF=0 compressor is always active.
Probes
-
rPO Thermostat probe calibration
(-12,0 ÷ 12,0; res. 0,1 °C /1°F)
-
EPP Evaporator probe presence (not present in the XB350C):
(no / YES)
no:
not present
(timed defrost);
YES:
present (end defrost )
-
EPO Evaporator probe calibration (not present in the XB350C):
(-12,0 ÷ 12,0; res. 0,1 °C
/1°F)
-
i1P Insert probe 1 presence (
no / YES)
no:
not present;
YES:
present.
-
i1o Insert probe 1 calibration
(-12,0 ÷ 12,0; res. 0,1 °C /1°F)
-
i2P Insert probe 2 presence (
no / YES)
no:
not present;
YES:
present.
-
i2o Insert probe 2 calibration
(-12,0 ÷ 12,0; res. 0,1 °C /1°F)
-
i3P Insert probe 3 presence (
no / YES)
no:
not present;
YES:
present.
-
i3o Insert probe 3 calibration
(-12,0 ÷ 12,0; res. 0,1 °C /1°F)
-
rEM End cycle probe selection
. (iPt, rP). It sets which probe stops teh the cycle, thermostat
probe or insert probe.
iPt
= insert probe;
rPt
=thermostat probe
NOTE, with rEM = rPt when the cycles are done by temperature, the rSi values are used
as stop of the cycle.
Display and measurement unit
-
CF Temperature measurement unit
: °C =Celsius; °F =Fahrenheit
-
rES Resolution (for °C)
:
in
: integer;
de
: with decimal point
-
Lod Upper display visualization:
select which probe is shown by the upper display:
rP
= Thermostat probe
EP
= Evaporator probe
-
rEd Remote display, X-REP, visualization:
select which probe is displayed by the X- REP:
rP
= Thermostat probe;
EP
= Evaporator probe;
tiM:
cycle count down;
i1P
= insert probe 1;
i2P
=
insert probe 2;
i3P
= insert probe 3.
Digital inputs
-
d1P: Door switch input polarity (25-26):
(OP÷CL) select if the digital input is activated by
opening or closing the contact.
OP
= opening;
CL
=closing.
-
odc Compressor and fan status when open door
:
no
= normal;
Fan
= Fan OFF;
CPr
= Compressor(s) OFF;
F_C
= Compressor(s) and fan OFF.
-
doA Open door alarm delay
:(0÷254min,nu) delay between the detection of the open door
condition and its alarm signaling: the flashing message “dA” is displayed. If doA=nu the door
alarm will be not signaled.
-
dLc Stop countdown of the running cycle with door open y =
countdown is stopped with
door open; n= countdown goes with door open;
-
rrd Regulation restart with door open alarm: y =
count down and regulation restart when door