User 

Manual Book 

Blast Chiller 

 
 
 
 
 

 
 
 
 
 

 

BZ 1014, BZ 1010, BZ 1005 

 

 

 

 

 

 

 

 

 

 

Содержание BZ 1005

Страница 1: ...User Manual Book BlastChiller BZ 1014 BZ1010 BZ1005 ...

Страница 2: ...m to deliver stylishly designed products equipped with state of the art technology to assist you in your daily activities This is your guidebook containing everything you need to know about our product Please reach out to us if you need further assistance or other information via our Customer Care or our official website www modena com ...

Страница 3: ...1 Regulation General Instruction 4 Part 2 Name of Parts 4 Part 3 Installation 5 Part 4 How to Use 7 Part 5 Cleaning Maintenance 28 Part 6 Troubleshooting 30 Part 7 Disposal 30 Part 8 Refrigerant Technical Card 31 Part 9 Specification 31 ...

Страница 4: ...n that should not be ignored B Replacement of Part Activate all necessary safety devices before carrying out any replacement intervention In particular turn off the power supply using the different disconnecting switch All responsibility is declined for injury to persons or damages on the components from using non original spare parts and intervensions which could modify the safety requisites with...

Страница 5: ...s manual book The lifting and transportation system of the packaged product envisions the use of a fork lift truck or a pallet stacker When using these particular attention must be paid to balance the weight to prevent the risk of overturning avoid excessive tilting ATTENTION When inserting the lifting device pay attention to the positions of power supply cable and the feet The packaging is made o...

Страница 6: ...as shown in the attachments The defrosting water and the water that forms at the bottom of the refrigerating compartment during operation or during periodical internal cleaning must be drained through a prearranged hose with a minimum diameter 3 4 connected to the hose at the bottom of the chiller The drainage should be installed as well The drainage must in compliance with the standards C Electri...

Страница 7: ...ructions in the manual book carefully Don t tamper or eliminate the installed safety devices Failure to comply with this requisite can lead to serious risks for personal health and safety It is recommended to simulate some test maneuvers to identify the controls in particular those relative to switch on and switch off and their main functions The appliance is only destined for the use for which it...

Страница 8: ...e longer If possible cool the food materials outside the appliance to the set temperature Check the planarity of the appliance rest surface Make sure the food does not touch the inner walls of the appliance to not obstruct the circulation of cold air There must be a sufficient space between the basins and trays used to guarantee a sufficient flow of cold air on the entire product Therefore avoid t...

Страница 9: ... time to shock freeze and the sizes cannot be reduced decrease the quantity and precool the chiller compartment by starting an empty shock freezing cycle before shock freezing the product Panel Control XB507L a General features The series XB has been created for fast chilling or freezing goods according to international food safety standards There are four types of cycles The cycles Cy1 Cy2 Cy3 Cy...

Страница 10: ...the maximum current allowed on each relay in case of heavier loads use a suitable external relay For the probe and digital input connectivity this appliance is equipped with terminal block screw for connecting wires with a cross section up to 2 5mm 2 Probes connection The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid infiltration It is recommended to place t...

Страница 11: ...mpressor and the fan will be stopped for the PAU time see parameters list and the flashing message Stb will be displayed To restart the cycle press and release the button the cycle will restart from the some point at which it was interrupted In any case the cycle automatically restarts after the PAU time How to stop a cycle Hold pushed the 2 START STOP button until the yellow LED will be switched ...

Страница 12: ... parameters 3 To modify a parameter push the SET button and use the arrow buttons 4 Confirm the new value by pushing the SET button 5 The new value is recorded even if the programming is exited by time out Buttonboard when a cycle 1 2 3 4 5 is running Display temperature The upper display shows the temperature of the thermostat probe the bottom display shows the temperature of a insert probe if en...

Страница 13: ...en the holding cycle is running H How to display the holding regulation set point While the holding cycle is running H icon lighted push the SET button and the holding set point is displayed on the UPPER display while the SETH label on the bottom display How to modify the room set point While SETH is displayed hold pushed the SET button till the SETH label starts flashing and LED near the SET butt...

Страница 14: ... menu Push the PRINTER 7 button for few seconds to enter the printer configuration menu The itP label is displayed use the ARROW buttons to browse the parameters To modify push the SET button and then the ARROW buttons To confirm push the SET button To exit the Printer menu Push together SET UP buttons or wait 5 sec How to start a manual defrost 1 Assure that none cycle is active or the hold mode ...

Страница 15: ...zing avoiding ice skin hard chill freezing cycle HLd hold mode function dEF for starting a manual defrost 2 Now the cycle is memorized and can be activated How to modify a cycle 1 Verify that none cycle is running If one cycle is running stop it by pushing the button for 3s 2 Push the to move among the cycles C1 C2 C3 C4 and the holding cycle The related symbol on the display will be lighted and t...

Страница 16: ...0 12 0 res 0 1 C 1 F i3P Insert probe 3 presence no YES no not present YES present i3o Insert probe 3 calibration 12 0 12 0 res 0 1 C 1 F rEM End cycle probe selection iPt rP It sets which probe stops teh the cycle thermostat probe or insert probe iPt insert probe rPt thermostat probe NOTE with rEM rPt when the cycles are done by temperature the rSi values are used as stop of the cycle Display and...

Страница 17: ...r it always is switched on during the Cycles during the holding depends on the2CH parameter Second relay management 2CH Compressors setting during the holding phase used only if one OAi C2 The second compressor is always switched on during the phases during the holding depends on this parameter The 2CH sets which compressor is used during the holding phase Second compressor operates on set OAS whi...

Страница 18: ... it temperature at the start of defrost SEt set point dEF dEF message Fdt Drip time 0 60 min Time interval between reaching defrosts termination temperature and the restoring of the controllers normal operation This time allows the evaporator to eliminate water drops that might have formed during defrost dAd Defrost display time out 0 120 min Sets the maximum time between the end of defrost and th...

Страница 19: ...cle is done 1 Every programmable cycle Cy1 Cy2 Cy3 or Cy4 can be divided into up to 3 phases usually called Hard chill Soft chill Freezing cycle 2 For each phase there are 3 parameters iS1 iS 2 iS 3 Set point related to the insert probes that stops the current phase rS1 rS2 rS3 set point of the room temperature for each phase Pd1 Pd2 Pd3 the maximum duration time for each phase Hds set point of th...

Страница 20: ...prevent the temperature to reach lower value in hard cycle Pd1 OFF 4 0h 10 minutes the maximum time for the first phase Is2 50 50 C 1 C 1 F Insert check point set when temperature measured by the three insert probes reaches this value the second phase is ended RS2 50 50 C 1 C 1 F Room set point probe for the seonc phase to prevent the temperature reahc lower value in the second phase PD2 OFF 4 0h ...

Страница 21: ...Freezing Cycle both compressor and fan are always on until the rS3 temperature is reached At this point compressor and fans are turned on end off so as to keep the temperature of the room at the rS3 value normally some degrees below iS3 Freezing Cycle ends when the temperature measured by the 3 insert probes reach the iS3 value normally 18 C 0 F in any case it ends when the maximum time Pd1 Pd2 Pd...

Страница 22: ...sket mod RG L The temperature range allowed for correct operation is 0 60 C Avoid places subject to strong vibrations corrosive gases excessive dirt or humidity The same recommendations apply to probes Let the air circulate by the cooling holes Cut out Mounting XB 7PR Printer optional The XB570L is designed to work with the XB07PR The XB07PR kit is composed by 1 Printer 2 Power adapter 3 Connectin...

Страница 23: ...23 Printer dimensions Printer mounting SCREW FIXING PANEL CUT OUT Connection to the XB570L XB07PR ...

Страница 24: ...amming HOT BUTTON The Wing units can UPLOAD or DOWNLOAD the parameter list from its own E2 internal memory to the Hot Button and vice versa Download from the HOT BUTTON to the instrument 1 Turn OFF the instrument by means of the ON OFF button remove the TTL serial cable if present insert the Hot Button and then turn the Wing ON 2 Automatically the parameter list of the Hot Button is downloaded int...

Страница 25: ...Alarm output ON Other outputs unchanged FF Fast freezing interrupted by shortpower failure Alarm output ON The freezing cycle restart from the same point at which was interrupted PFA Fast freezing interrupted by long power failure Alarm output ON The freezing cycle restart from the current phase OCF Max duration of the cycle is expired Alarm output ON Other outputs unchanged In any case the cycle ...

Страница 26: ...with holding CyS tEP iS2 5 C Pd3 4 0 h dbC YES rS2 2 C dbH YES iS1 8 C Pd2 2 0 h HdS 21 C rS1 10 C iS3 18 C Pd1 2 0 h rS3 28 C Cy3 direct fast freezing with holding CyS tEP iS2 18 C Pd3 4 dbC yes rS2 28 C dbH yes iS1 18 C Pd2 OFF HdS 21 C rS1 28 C iS3 18 C Pd1 4 0 rS3 28 C Cy4 direct fast freezing without holding CyS tEP iS2 18 C Pd3 OFF dbC yes rS2 28 C dbH no iS1 18 C Pd2 OFF HdS OFF rS1 28 C iS...

Страница 27: ...y function tMr Pr2 oA2 Second configurable relay function ALL Pr2 oA3 Third configurable relay function Lig Pr2 2CH Compressor setting during the holding C1 Pr2 OAt Second compressor switching on delay 3 Pr2 OAS Set point for second compressor 0 Pr2 OAH Differential for second compressor 2 0 Pr2 OAi Probe selection for second compressor rP Pr2 OSt Auxiliary output timer 0 Pr2 OSS Set point for aux...

Страница 28: ...t uses iron wool brushes or scrapers to clean the stainless steel as ferrous particles could be deposited which on oxidizing could lead to rust To remove hardened residues use wooden or plastic spatulas or abrasive rubber pads During long periods of inactivity spread a protective layer on all stainless steel surfaces by wiping them with a cloth soaked in Vaseline oil and airing the rooms periodica...

Страница 29: ...ence of dust Whenever the condenser has a deposit of dust in correspondence with the fins this can be removed using a suction device or with a brush applied using a vertical movement along the direction of the fins No other instruments must be used which may deform the fins and therefore the efficiency of the appliance To clean proceed as follows 1 Open the door A of the appliances 2 Remove the lo...

Страница 30: ... MODENA Call Center Circuit board fault Contact MODENA Call Center Presence of ice inside the evaporator Carry out a defrosting cycle possibly with the door open If the problem persists contact MODENA Call Center Appliance noise Persistent vibrations Check there is no contact between the appliance and other objects inside or outside This appliance is marked in compliance with the 2002 96 EC Europe...

Страница 31: ...ons are inhaled go into the open air Keep the person calm If the person cannot breath perform artificial respiration If respiration is difficult apply oxygen Consult a doctor BZ 1014 BZ 1010 Blast Chiller Freezer Blast Chiller Freezer Ventilated cooling system Ventilated cooling system Automatic Defrost No Frost Automatic Defrost No Frost Interior structure in Stainless steel 304 Interior structur...

Страница 32: ... Freezer 70 C to 18 C in 240 minutes Specifications of this appliance may change without notice to improve the quality of the product Pictures in this manual are schematic and may not match your product exactly Values stated on the machine labels or in the documentation accompanying it are obtained in laboratory in accordance with the relevant standards Depending on operational and environmental c...