Installation
19
IMPORTANT SAFETY NOTES:
•
Isolate (turn off) the mains power at the main consumer unit (fuse box) before commencing
installation or performing any maintenance, including changing blown light fittings.
•
SceneStyle is designed to control light fittings at mains voltage or low voltage when fed
from a suitable electronic transformer. To avoid hazard or possible damage do not use with
inductive, fluorescent, wire wound transformer or motor loads.
•
SceneStyle must be installed by a qualified electrician or other competent person.
Installation should be in accordance with the National Wiring Regulations or other applicable
regulations. Compliance with the EC EMC or Low Voltage Directives may be invalidated if
not used or installed to the published specification.
•
SceneStyle is for installation to 230V and 240V single phase mains supplies only. The cable
connected to the live input terminal must be capable of supplying the total current for all
circuits (4A maximum).
•
SceneStyle must be protected by an external circuit breaker or fuse rated at 6A maximum.
•
SceneStyle is a Class 1 product. This unit must be earthed.
•
SceneStyle must be installed in a suitable UK double gang backbox, compliant to BS4662
or BS5733. We recommend that a 47mm depth backbox is used.
•
SceneStyle complies with EN60669-1/EN60669-2-1, EN55015 and EN61547.
•
For indoor use only, at temperatures between 0°C and +25°C
•
Do not operate without the front fascia plate correctly fitted.
•
SceneStyle is suitable for 12V halogen lamps using only electronic transformers and not
wire wound or toroidal. Suitable electronic low voltage lighting transformers are manufactured
by Mode Lighting Ltd. Please contact your SceneStyle stockist regarding the correct product
for your installation. You may connect 240V GLS and GU10 light fittings to SceneStyle.
•
SceneStyle’s circuits will shut down if short-circuited or overloaded. This is indicated by the
circuits respective button flashing red.
•
The fascia will become warm during operation. This is normal.
Содержание SceneStyLED4
Страница 1: ...For more information please visit www modelighting com User Guide ...
Страница 26: ...Configuration Menus 25 CONFIGURATION MENUS See Operation Configuration Menu p 11 ...
Страница 27: ...Configuration Menus 26 See Circuit Configuration Menu p 12 See Remote Switch Configuration Menu p 15 ...
Страница 28: ...Scene Programming 27 SCENE PROGRAMMING ...
Страница 29: ...Scene Programming 28 ...
Страница 31: ...Notes 30 ...