Remote - Web Browser Session
MA 850 Installation and Configuration Guide
29
•
Channel status – under
Amp 1 to Amp 4
for the corresponding channel:
•
OK – channel OK
•
Fail – channel failure
•
AP Status:
•
OK – AP detected
•
Fail – AP not detected at the port.
4.2
Remote - Web Browser Session
NOTE: Be sure that there is not an open local session (section
4.1) to the MA 850 unit
before you attempt to open a remote session to the same unit; otherwise, the unit
may stop responding.
MA 850 whose SNMP parameters are defined may be connected to the network through an
Ethernet connection and assigned addresses either through dynamic (DHCP) or static address
assignment methods. The MA 850 units may then be remotely managed from any Web Browser
by connecting to the IP Address of the specific MA 850 unit or through any Network Operating
Center (NOC) using SNMP.
Once the network connections have been defined (section
4.2.1), the following operations may
be performed remotely through a Web browser:
•
Configure gain setting for each channel (section
4.3)
•
View alarms (section
4.4)
Figure
4-3. MA 850 Remote Management