Add-on to an MA 1000 System Installation
MA 850 Installation and Configuration Guide
18
8. Connect the
power.
It is recommended to use the following power supply for local power
configuration, where p
ower can also be supplied using remote power supply configurations
:
•
Dedicated power supply (i.e. LPS-48-100W which feeds both modules). Refer to the
Power Supplies Manual.
9. Connect the coax
antenna
cables to the MA 850 unit antenna ports on the MA 850 front
panel according to the following instructions:
•
Use 50 Ω, N-type male to male, 1/2” or 3/8” Plenum coax cables
•
Max cable length (typically): 150’
10. Fit 50 ohm terminators on all unconnected SMA, AP and antenna ports.