Add-on to an MA 1000 with MA 1200
MA 850 Installation and Configuration Guide
20
2. Mount the MA 850 and bracket assembly to the wall. When mounting, consider the
following:
•
The type of screws used to mount the unit must suit the type of wall construction
(cement, bricks, etc.) so that the mount is secure.
•
The position of the APs and required cable connections.
3. Assemble the MA 1000/1200 assembly to the 850 bracket.
4. For antenna sensing support (RHU 1000 version 3.1 and higher), connect between the
Control
connectors at the rear of both units using cable
705102101.
NOTE:
For antenna sensing support in RHU 1000 version 3.0 and lower, upgrade to a higher version
according to the
MA 850 Upgrade Procedure Guide.
5. Connect the 802.11b/g Access Points to the corresponding ports on the MA 850 rear panel.
Refer to section
1.5 for a description of the connections and distribution patterns.
NOTE:
It is recommended to RESET the unit by removing and reinserting the power connector on the
front panel after connecting the APs.
6. Connect the network connection to the MA 850 rear panel network port.
NOTE 1:
Each unit is pre-assigned an IP address. The address can be modified anytime through a
remote connection according to the procedure described in section
4.2.1).
NOTE 2:
It is recommended to record the location of the units according to the MAC addresses on the
sticker at the rear of the units near the Ethernet port.
705102101 connector
802.11b/g/ AP
connections
Ethernet
connection
MAC
Address
MA 1000 RHU
MA 850