Add-on to an MA 1000 System Installation
MA 850 Installation and Configuration Guide
17
NOTE:
For antenna sensing support in RHU 1000 version 3.0 and lower, upgrade to a higher version
according to the
MA 850 Upgrade Procedure Guide.
5. Connect the 802.11b/g Access Points to the corresponding ports on the MA 850 rear panel.
Refer to section
1.5 for a description of the connections and distribution patterns.
NOTE:
It is recommended to RESET the unit by removing and reinserting the power connector on the
front panel after connecting the APs.
6. Connect the network connection to the MA 850 rear panel network port.
NOTE 1:
Each unit is pre-assigned an IP address. The address can be modified anytime through a
remote connection according to the procedure described in section
4.2.1).
NOTE 2:
It is recommended to record the location of the units according to the MAC addresses on the
sticker at the rear of the units near the Ethernet port.
7. Connect the
MA 1000 antenna
ports
and the
MA 850 Mobile Services
ports using the
four SMA to N-type cables
supplied in the accessory kit
.
NOTE:
Be sure the connectors are closed at a 45 degree angle so as not to place stress on the cables.
AP status
MA 850
MA 1000 RHU
Power
Antenna connections
N-type SMA
jumpers (included)
802.11b/g/ AP
connections
705102101 connector
Ethernet
connection
MAC
Address
MA 1000 RHU
MA 850