Slave clock lines
12.1 Line type / Terminals:
Impulse
DCF
DCF-Imp
MOBALine
No. of lines
ETC 12(R)
*
1
ETC 14(R)
*
1
ETC 24(R)
*
2
Connection terminals:
All slave clock lines can be individually configured as type “Impulse”, “DCF” or "DCF-Imp". The
type “Impulse” allows to output polarised 1-minute-, ½-minute-, 1/5-minute-, 1/8-minute- or 1-
second-impulses (refer to 12.4.4) . The type “DCF” outputs a synthetic, active – time code. You
are free to choose the suitable signal from six modes (refer to 12.5.4). The line type "DCF imp"
combines the output of a synthetic, active DCF 77 – time code and the function of a 1-min-
impulse line with alternating impulse polarity (refer to 12.6). If your ETC is capable to output
MOBALine time code for self-setting slave clocks you can further set the type to “MOBALine”.
Slave clock lines 1+2 ETC 24R
21 22
1b 1a 2b 2a
23 24
1
4
Slave clock line ETC 14R
16 17
b
a
1
2
Slave clock line ETC 12R
12 13
b
a
1
2
1
2
1a
1b
Slave clock line ETC 12/14
1
2
3
4
1a
2a
1b
2b
Slave clock lines 1+2 ETC 24
* Standard settings