© MOBATIME
30 / 40
800845.01
9
Update firmware
9.1
Update firmware using RS232
Switch-off the clock.
Install and run the Flash Magic software.
Open the configuration file „dc3prog.fms“ over the File -> Open Settings
menu
Set used COM Port and open file firmware „dc3.hex“using the Browse key
Connect the programmer to serial COM Port of computer (the USB-RS232
converter can be used) and connect the power supply to the jack on the
programmer.
Install the jumper ISPE (JP9).
Connect the programmer to connector PROG (JP8), LED POWER placed on
the clock lights up.
Click the Start button to run programming, after completion a “Finished”
message will be displayed in the bottom part of the widow
Disconnect the programmer and remove the ISPE jumper.
Firmware version can be checked in the last item of clock menu.
9.2
Update firmware over Ethernet at NTP version
Create a folder on the computer disk and copy "tftpd32.ini", "tftpd32.chm" and
"tftpd32.exe" in it. Copy the file of new firmware "dc3app.bin" as well.
Run "tftpd32.exe" let only TFTP Server in the window Settings -> Global
Settings set, don’t change other settings.
By the Browse key open choice of active directory and find the one which
contains the given firmware
Connect to the clock by the windows command
telnet <ip clock address>
example: telnet 192.168.0.190
The page of telnet requesting will appear, after the password entered
identification of current software version and clock MAC address displays.
Enter the command
fu
in telnet window for start the automatic update clock
firmware from the "dc3app.bin" file.
Information about sending file and its progress displays in the tftpd32
programme window after the command entering. Connection to telnet is
ended automatically.
Wait about 1 minute after end of sending. Connect the telnet to clock again.
After entering the password, check if the firmware version is correct, if it isn’t,
it is necessary to repeat the whole procedure.
Close the telnet window and end the program tftpd32 with the command
exit
.