© MOBATIME
25 / 40
800845.01
Enter temperature correction value in format
xx.x
, the range is from -9.9 to +9.9
degrees.
Push the
>>
button to move to the communication mode setting.
The display shows
L : x
.
When a
0
value is set, the display works as a master on the RS-485 bus, value
1
means the display works only as a listener on the bus. On the single RS485 bus
just one display device must be master and the others must be listeners.
By pushing
OK
, the entered values are stored and the display returns to the
menu item
P13
(or
P14
or
P15
respectively). By pushing
ESC
return without
storing.
6.9
Settings for the TP LAN temperature sensors
Set the value
3
in the
P13
(or
P14
or
P15
respectively) menu item, and then by
pushing the
SET
enter the submenu for setting the IP address, measured
temperature correction and timing value. The item to be set is blinking.
Set four octets of the IP address of NTP server step
by step. Switch to another octet/digit by pushing the
<<
and
>>
buttons. Octets are marked by letters
A
,
b
,
C
and
d
.
After entering the last octet push the
>>
button to move to the temperature
correction setting.
The display shows
cxx.x
.
Enter temperature correction value in format
xx.x
, the range is from -9.9 to +9.9
degrees.
Push the
>>
button to move to the timing value setting.
The display shows
n :xx
.
Set the value
xx
according to predicted number of display units, which should
communicate with the actual temperature sensor. Then the apropriate timing for
the communication with the sensor is applied.
By pushing
OK
, the entered values are stored and the display returns to the
menu
6.10
Manual setting of the IP address of the clock
Choose the item
P18
in the main menu and push the
SET
button to enter the
submenu for setting the IP address. The item to be set is blinking.
The display shows the following:
Enter four octets of the IP address step
by step. Switch to another octet by
pushing the
<<
and
>>
buttons. Octets
are marked by letters
A
,
b
,
C
and
d
.
By pushing
OK,
the entered values are stored and the clock returns to the menu
item
P18.
By pushing
ESC
the clock returns to
P18
without storing.
6.11
Manual setting of the subnet mask
Choose the item
P19
in the main menu and push the
SET
button to enter the
submenu for setting the subnet mask. The item to be set is blinking.
Содержание DT.100.1C.1T