Setting the network parameters for NTP versions
In the item
P17
choose if the network parameters (IP address, subnet mask, gateway NTP
servers) will be set automatically (DHCP), or manually (telnet, the clock menu), or they will not
be assigned at all (e.g. for NTP multicast).
5.1
Manually setting the network parameters using clock Menu
According to chapter 6.10 set clock’s IP address in item
P18
submenu
According to chap 6.11 set subnet mask in item
P19
submenu
According to chap 6.12 set gateway in item
P20
submenu
5.2
Manually setting the network parameters using telnet
Prior to the first connection using telnet, it is necessary to make the following
procedure because initial IP address is 0.0.0.0.:
by windows command
arp -s <IP address> <MAC address>
match new IP
address to clock’s MAC address (it is marked on the label next to RJ-45
connector)
example: arp -s 192.168.0.190 00-16-91-FE-90-00
reset the clock or just turn it off/on and do the following within 2 minutes:
by windows command
ping <IP address>
is this IP address temporary
assigned to the clock (it is valid only in case if current IP address is 0.0.0.0),
clock should answer two last ECHO requests at least
example: ping 192.168.0.190
do the following within 30 seconds:
by windows command
telnet <IP address>
connect to clock and make
needed setting (see lower) – set the new IP address at first and correct other
parameters if necessary
example: telnet 192.168.0.190
Setting parameters over telnet:
request for the password appears after connection (default password is
718084)
the software and hardware version and MAC address displays if password
entering was successful
inserted commands can be send off using Enter key, the Backspace key
serves for
correction of the typing errors
command
help
or
?
displays help with command’s list
command
reset
makes clock reset (setting modifications are written to data
flash)
command
conf -p
displays current setting of the menu parameters
command
conf –n
displays current network parameters
command
conf -?
displays help for command conf parameters
example: conf -i 192.168.0.190 set clock IP address to 192.168.0.190
it is necessary to end telnet by command
exit