3.
Solar Calculations
3.1
Open Circuit Input Calculations
The Nomad PV input ports has an operating range of 65-350Vdc.
When choosing the number of panels in series to connect to each Nomad port, consult the PV panel
specifications sheet and use the following formula:
Maximum panels per string
≤
375 / (
𝑉𝑉
𝑜𝑜𝑜𝑜
+ (
𝑉𝑉
𝑜𝑜𝑜𝑜
× (
𝑇𝑇
𝑚𝑚𝑚𝑚𝑚𝑚
−
25) x
𝑇𝑇
𝑜𝑜
/ 100))
With:
𝑉𝑉
𝑜𝑜𝑜𝑜
– Open circuit voltage at STC
𝑇𝑇
𝑚𝑚𝑚𝑚𝑚𝑚
– Coldest ambient temperature the PV panels will ever be exposed to
𝑇𝑇
𝑜𝑜
– Temperature coefficient of
𝑉𝑉
𝑜𝑜𝑜𝑜
in
% °
𝐾𝐾
⁄
Warning:
PV input voltages above 400Vdc will cause system damage and void the
product warranty.
NOMAD USER MANUAL
PAGE
13