Architecture
Forced Air Cooling
Compliance
IEC62109-1
1.3.5
Climatic Conditions
Ambient Temperature
-10 to 60 °C (derated above 40°C)
Ambient Transport Temperature
-25 .. 70 °C
Maximum Ambient for Rated Power
40 °C
Relative Humidity (Non-Condensing)
5 .. 85 %
Maximum Altitude for Rated Power
1000 m above sea level
(Power derated for High Altitude)
1.3.6
Operator Panel
Display Type
Full colour Touch screen 4.3 inch LCD
Graphs
24 hour history display of solar power production (both
ports), battery and most recent sweep graph (both
ports)
Data and Event Logs
Daily solar production (kWh) and peak power (kW).
Logging of system events.
All specifications listed above performed at nominal voltage, frequency and temperature unless
otherwise noted.
1.3.7
Altitude Derating
Figure 1: De-rating the Nomad charge controller output power at high altitude
75
85
95
105
0
1000
2000
3000
4000
Per
cen
ta
ge o
f R
at
ed
Po
wer
Altitude in meters above Sealevel
Altitude Derating