background image

13

IDL280-LM Series

Long Travel Industrial Linear Stages

Unscrew and remove 8 mounting rods of the lifting rings and the

locking plate.

5.3

Mounting Conditions

IDL280-LM stages feature an eight-point mounting pattern which is ideal for

non-flat surfaces. However it is recommended for all IDL280-LM stages that

the following mounting conditions be adhered to for best performance and

securiry.

5.4

Air Blowing

When used in dusty environment (dust, debris…), the stage can be

protected by connecting an air source to the air tube plug (see sections

4.8 & 8.0 of this manual). This will prevent pollution from coming in by

slightly increasing stage internal pressure. Such air injection can also be

used to improve motor heat dissipation and limit temperature increase.

Here are the required characteristics for the air source:

Pressure: 6.0 bars

Particle size: 5 µm

Particle density: 5 mg/m

3

Dew point: -20 °C

Gas Oil ratio: 1 mg/m

3

Installation Considerations

<400 mm Travel

<800 mm Travel

Mounting surface flatness

10 µm

15 µm

Payload surface flatness

20 µm

20 µm

Mounting Screw torque

M8: 16.0 Nm

M6: 7.0 Nm

M5: 4.1 Nm

M4: 2.1 Nm

A1045F0 - EDH0362En1050 — 02/20

Содержание Newport IDL280-1200LM

Страница 1: ...G U ARANTE E D S P E CIFICATIO N S Long Travel Industrial Linear Stages IDL280 LM Series USER S MANUAL A1045F...

Страница 2: ...essed or implied including any implied warranty of merchantability or fitness for a particular use Newport Corporation shall not be liable for any indirect special or consequential damages by Newport...

Страница 3: ...teristics and Stiffness 5 3 5 Stage Weights 5 4 0 Drive and Motor 6 4 1 Motor characteristics Direct Drive Brushless Motor 6 4 2 Command Signals 6 4 3 Sensor Positions 7 4 4 Position Feedback Signals...

Страница 4: ...s 14 6 1 Warnings on Controllers 14 6 2 Connection 15 6 3 Cables 15 6 4 Adapter for the XPS D Newport Controller 15 7 0 Connection to Non Newport Controllers 16 8 0 Dimensions 17 9 0 Maintenance 17 9...

Страница 5: ...rector ra Physics Z France tial requirem risk exists w isions of the ce with the r ying good en isions of the ce with the f of machinery ectrical equip al requireme Safety of ma hnical docum he releva...

Страница 6: ...be used in this manual to call attention to important information regarding personal safety safety and preservation of the equipment or important tips WARNING Warning indicates a potentially dangerous...

Страница 7: ...cified by Newport the safety features provided by the stage can be impaired WARNING Very fast moving parts of the stage or any attachments can cause crushing or shearing injuries All personnel must re...

Страница 8: ...jects into this stage this may cause an electric shock or lock the drive Do not use this stage if any foreign objects have entered the stage Switch off the motor power and then disconnect the electron...

Страница 9: ...e temperature 10 to 40 C in its original packaging CAUTION Do not move this stage if its motor power is on Make sure that the cable to the electronics is disconnected before moving the stage Failure t...

Страница 10: ...x IDL280 LM Series Long Travel Industrial Linear Stages A1045F0 EDH0362En1050 02 20...

Страница 11: ...d and understand this user s manual before operating an IDL280 LM stage Inside this manual you will find useful information and technical references It is recommended the user download all support doc...

Страница 12: ...rect read linear encoder all components were selected to enable the high precision and dynamic performance expected of high throughput and demanding applications Other features include positive and ne...

Страница 13: ...f a system to achieve a commanded position over many attempts Reversal Value Hysteresis Difference between actual position values obtained for a given target position when approached from opposite dir...

Страница 14: ...function of applied load This curve defines allowed operating conditions to stop within the 0 35 in 9 mm over travel allowed by the hard stops To stop within this distance the user must maintain spee...

Страница 15: ...Q D Cz X k y k z k x Cx Cz Normal center load capacity on bearings 1500 N Cx Axial Load Continuous 221 N kax Angular stiffness Roll 0 3 rad Nm kay Angular stiffness Pitch 0 3 rad Nm kaz Angular stiff...

Страница 16: ...tive to V Continuous force coil 100 C 221 N Continuous force 3 bar Air Cooling coil 100 C 265 N Peak force 1248 N Motor constant 335 N2 W Continuous power 97 5 W Peak power 3110 W Electrical cycle 60...

Страница 17: ...5 520 5 9 0 IDL280 400LM 8 29 0 0 35 8 41 0 02 16 36 0 04 24 31 0 02 24 43 0 35 0 210 5 0 9 213 5 0 5 415 5 1 617 5 0 5 620 5 9 0 IDL280 600LM 8 29 0 0 35 8 41 0 02 20 30 0 04 32 19 0 02 32 30 0 35 0...

Страница 18: ...Gnd T T A A B B I I 5 V 0 V Ha Hb Hc i2c Data i2c Clock ZM FC FC Fault Inhibit U command Gnd V command Gnd Driver Gnd V command Gnd U command Inhibit Fault FC FC ZM i2c Clock i2c Data 1 5 V 2 N C 3 N...

Страница 19: ...ius 33 mm Encoder Cable Cable 4 25 mm Min dynamic bending radius 20 mm SUB D15F Connector 7 8 14 1 6 Connector Cap IDL LM Ha Hb Hc 5 V Ground Hall Effect Sensor 9 10 18 26 19 1 1 5 V 2 N C 3 N C 4 Enc...

Страница 20: ...m with Legris connector ref 3606 06 00 Min dynamic bending radius 27 mm DB9W4M Connector A1 A2 A3 A4 1 2 Connector Cap IDL LM Phase U Motor Phase V Motor Phase W Motor Ground Shield T T Motor A1 A2 A3...

Страница 21: ...stage especially for configurations where the weight is higher than 132 lb 60 kg NOTE Allen keys are supplied for CHc M6 and CHc M8 screws as well a 13 mm open end wrench for dismantling the spacer t...

Страница 22: ...fting rings fixed on the rods Unscrew with the supplied Allen key 4 CHc M8 screws from the 2 locking brackets on rods Unscrew with the supplied Allen key 4 CHc M6 screws from the 2 locking brackets on...

Страница 23: ...be protected by connecting an air source to the air tube plug see sections 4 8 8 0 of this manual This will prevent pollution from coming in by slightly increasing stage internal pressure Such air in...

Страница 24: ...unit CAUTION To protect the unit from damage be sure to Keep all air vents free of dirt and dust Keep all liquids away from the unit Do not expose the unit to excessive moisture 85 humidity Read this...

Страница 25: ...cables that can be directly connected to the Newport controller WARNING IDL280 LM Series translation stages can only operate with cable lengths of 4 5 m or less WARNING These cables are shielded For...

Страница 26: ...nd Specifications for more information to help configure the stage with your controller Newport also provides a tech note on configuring third party stages with Newport controllers in the IDL280 LM we...

Страница 27: ...1631 667 435 1 INCLUDING OVER TRAVEL ALLOWED BY THE HARD STOP 12 05 306 BOTH SIDES 4 HOLES M4 THD DEPTH 31 8 2 56 65 3 94 100 79 20 3 94 100 A 1 AT MAX TRAVEL A 1 AT MAX TRAVEL 71 18 10 24 260 49 12...

Страница 28: ...ed to return the stage to Newport for re lubrication after 2000 hours of use If the IDL280 LM stage is mounted on a workstation and cannot be easily removed please contact Newport s After Sales Servic...

Страница 29: ...Country P O Number Item s Being Returned Model Description Reasons of return of goods please list any specific problems Return authorization Please obtain prior to return of item Date Phone Number Fa...

Страница 30: ...sales newport com Technical Support Tel 800 222 6440 e mail tech newport com Service RMAs Returns Tel 800 222 6440 e mail service newport com Europe MICRO CONTROLE Spectra Physics S A S 9 rue du Bois...

Отзывы: