6
IDL280-LM Series
Long Travel Industrial Linear Stages
4.0 —
Drive and Motor
4.1
Motor characteristics (Direct Drive Brushless Motor)
CAUTION
High RMS current will generate motor heating which will degrade
characteristics of the stage, such as repeatability, accuracy, etc…
4.2
Command Signals
NOTE
The values above indicate voltage induced by energized coil of one
phase on next phase coil. A positive value for U-V would indicate a
higher voltage on U relative to V.
Continuous force, coil @ 100 °C
221 N
Continuous force, 3-bar Air Cooling, coil @ 100 °C
265 N
Peak force
1248 N
Motor constant
335 N
2
/W
Continuous power
97.5 W
Peak power
3110 W
Electrical cycle
60 mm
Max. bus voltage
330 V
Max. coil temperature
125 °C
Thermal dissipation constant
1.95 W/°C
Continuous current
4.6 Arms
Continuous current, AC
5.5 Arms
Peak current
26.0 Arms
Force constant
48.0 N/Arms
Back-emf constant
39.2 V/m/s
Inductance
3.50 mH
Thermal resistance @ 25 °C
4.60
Ω
Electrical time constant
0.76 ms