7
IDL280-LM Series
Long Travel Industrial Linear Stages
4.3
Sensor Positions
4.4
Position Feedback Signals
– End-of-Run Limit
+ End-of-Run Limit
Index Pulse
Index Pulse
Motion
Dir
Direction –
1.97
(50)
.08 (2)
.08 (2)
Negative
Software Limit
Stage Travel Range
Positive
Software Limit
Home Position
(Origin)
Dimensions in inches
(and millimeters)
Dir
X
X Values
– Hard
– End-of-Run
Home
+ End-of-Run
+ Hard
[in. (mm)]
Stop
Limit
Position
Limit
Stop
IDL280-300LM
8.29
0
-0.35
8.41
±0.02
14.39
±0.04
20.37
±0.02
20.49
+0.35
0
(210.5
0
-9
)
(213.5
±0.5
)
(365.5
±1
)
(517.5
±0.5
)
(520.5
+9
0
)
IDL280-400LM
8.29
0
-0.35
8.41
±0.02
16.36
±0.04
24.31
±0.02
24.43
+0.35
0
(210.5
0
-9
)
(213.5
±0.5
)
(415.5
±1
)
(617.5
±0.5
)
(620.5
+9
0
)
IDL280-600LM
8.29
0
-0.35
8.41
±0.02
20.30
±0.04
32.19
±0.02
32.30
+0.35
0
(210.5
0
-9
)
(213.5
±0.5
)
(515.5
±1
)
(817.5
±0.5
)
(820.5
+9
0
)
IDL280-1200LM
8.29
0
-0.35
8.41
±0.02
28.17
±0.04
47.91
±0.02
48.05
+0.35
0
(210.5
0
-9
)
(213.5
±0.5
)
(715.5
±1
)
(1217.5
±0.5
)
(1220.5
+9
0
)
Signal description/Voltage/Wiring
Heidenhain standard 1 Vpp
Reference mark position
see drawing "Sensor Positions"
Resolution
Scale pitch 20 µm
Maximum speed
8 m/s
Low
High
Low
High
Low
High
Low
High
Encoder
Phase A
Encoder
Phase A
Encoder
Phase B
Encoder
Phase B
1
2
3
4
Encoder Feedback Signal Position
Motion
Dir
Direction –
Dir
A1045F0 - EDH0362En1050 — 02/20