System
Installation
18
elite
TM
2.2
Installation
Requirements
2.2.1
elite
TM
Airflow
Requirements
A
minimum
space
of
75
mm
(3”)
should
be
allowed
front,
rear
and
sides
for
ventilation.
Approximately
160
CFM
(4530
liters/min)
of
airflow
is
required.
2.2.2
Power
Requirements
The
AC
Input
Ratings
of
the
elite
TM
Generator
are
indicated
on
a
label
attached
to
its
back
panel.
Those
nominal
ratings
are
as
follows:
100
VAC
–
264VAC,
50/60Hz,
15A,
Single
Phase
Upstream
Disconnect
Device
Safety
listing
of
model
elite
TM
generator
requires
that
its
installation
include
an
upstream
current
‐
limiting
disconnect
device
rated
50
‐
60
Hz,
250V
~
minimum,
and
no
more
than
20A.
The
upstream
disconnect
device
must
be
located
within
sight
of
the
elite
TM
unit,
must
remain
user
‐
accessible
at
all
times,
and
must
be
labeled
so
as
to
indicate
the
equipment
it
disconnects.
During
installation,
removal,
and/or
servicing
of
the
elite
TM
unit,
place
the
upstream
disconnect
device
into
its
off
(open)
position,
and
follow
lock
and
tag
(lock
‐
out
/
tag
‐
out)
procedures
to
control
hazardous
energy
(reference
appropriate
regional
regulations
and
requirements).
No
circuit
should
be
connected
or
wired
when
electricity
is
present.
For
safety
compliance,
the
elite
TM
must
be
powered
with
a
connection
that
has
a
hardware
‐
based
EMO
circuit.