- Page 14
This will give a weld procedure printout, first showing the description of
the procedure, followed by the all the welding parameters, then by Limit
and Deviation parameters, then by the actual strip chart of the weld
amperage, arc voltage and motor speed.
Program List
Press this button to printout the complete listing of all the weld
procedures saved in the memory of the unit.
Calibration Report
To obtain a printout of the calibration values for the motor, motor-
tachometer feedback, current and voltage scales, press this button.
Print Option
This button controls the Deviation Report printout after each weld. There
are only three options available for this printout, they are as follows:
NEVER, ALWAYS & FAULTS.
In the NEVER mode, a printout of the weld will only occur if the
PRINT WELD button is pressed.
In the ALWAYS mode, at the end of every weld once the rotor
returns to the home position, it will automatically printout the
resultant Strip Chart as if the PRINT WELD button had been
pressed.
In the FAULTS mode, a Strip Chart will only printout if there were
deviations in the weld sequence.
Section 13
Calibration Menu
Prior to using the CobraTig 150 SM unit for welding, it is generally a good
idea to calibrate the output and feedback readings prior to striking an arc.
Options from the CALIBRATION MENU include motor output and tachometer
feedback, current output and feedback, and arc voltage input.
In order to properly calibrate this machine, you will need the following: DC
power supply capable of producing 1.0 VDC to 20.0 VDC, a certified digital
multimeter, and various standard connection leads. To aid in the calibration
of this machine, purchase kit P/N 005-0251 (The instructions included with
the kit are for the model ACL Orbital Welder, they do not apply to this unit).
Use the instructions on the HELP screen for a full explanation on how to
calibrate this unit.
Help
Press this button to read a brief description of the CALIBRATION MENU
button descriptions and functions.
Main Menu
Press this button to return to the MAIN MENU.
1.8 VDC Calibration / 18 VDC Calibration
These two keys are used in conjunction for calibrating the arc voltage
feedback circuit. Use the information on the HELP screen to perform
this calibration procedure.