CobraTig
®
150 Owner's Manual
- Page 7
•
Press F4 or F9 and scroll to Curr. L. (A), low weld current in amps.
•
Press F5 or F10 and enter Low current value from 0.2~150 amps.
•
Press F4 or F9 and scroll to Pulse H. (S), high weld current pulse
time.
•
Press F5 or F10 and enter High weld current pulse time from
0.00~0.99 seconds.
•
Press F4 or F9 and scroll to Pulse L. (S), low weld current pulse
time.
•
Press F5 or F10 and enter Low weld current pulse time from
0.00~0.99 seconds.
•
Press F4 or F9 and scroll to Pre-Gas (S), pre-purge gas time.
•
Press F5 or F10 and enter pre-purge gas time from 0.0~9.9 seconds.
•
Press F4 or F9 and scroll to Post-Gas (S), post-purge gas time.
•
Press F5 or F10 and enter post-purge gas time from 0.0~9.9
seconds.
•
Press F4 or F9 and scroll to Strike (A), arc strike weld current.
•
Press F5 or F10 and enter arc strike weld current from 0.1~25.0
amps.
•
Press Foot Control to maximum and hold for duration of weld
•
Press F6 Print Weld wave form graphics from integral printer
WELD MANUAL SCREEN DISPLAY
•
F1, Start/Stop, used for manual Start/Stop operations without a foot
control.
•
F2, Main Menu, returns to the Main Menu display.
•
F3, Weld Orbital, returns to the Weld Orbital display.
•
F4, Scroll UP, scrolls the highlighted field from one demand
parameter to the next demand parameter.
•
F5, Adjust Up, increases the numerical value of the demand
parameter selected. As this button is pressed for each parameter a
vertical bar graph displays the increasing value, both numerically and
graphically from the bar graph. For most parameters, a maximum
value is obtained once the vertical bar graph has reached the top of
the scale. Also, there is a change in the sound once the top of the
scale has been reached. The sound changes from a single beep to a
triple beep.
•
F6, Print Weld, Data-Monitoring of manual weld produces a graphical
real time wave form of welding amps and arc volts.
•
F7, Pedal On, selects the variable remote foot control for operation.
•
F7, Pedal Off, selects the On/Off switch control and permits additional
programming of weld current Upslope time in seconds and Final
Slope weld current time in seconds.
•
F8, Blank, no function control.
•
F9, Scroll Down, scrolls the highlighted field from one demand
parameter to the next demand parameter.
•
F10, Adjust Down, decreases the numerical value of the demand
parameter selected. As this button is pressed for each parameter a
vertical bar graph displays the decreasing value, both numerically
and graphically from the bar graph. For most parameters, a minimum
value is obtained once the vertical bar graph has reached the bottom
Содержание CobraTig 150 SM
Страница 7: ......
Страница 27: ...THIS PAGE INTENTIONALLY BLANK...
Страница 28: ...DATE August 1 2010 16882 Armstrong Ave Irvine CA 92606 Tel 949 863 1234 Fax 949 474 1428 www mkproducts com...
Страница 29: ...16882 ARMSTRONG AVE IRVINE CA 92606 TEL 949 863 1234 FAX 949 474 1428 WWW MKPRODUCTS COM...