55
D
ESK
T
OP
S
ERIES
–
AUTOMATIC OPERATION
WARNING:
Preventive maintenance may only be done by qualified, trained
persons
The materials, parts, and tools necessary for the maintenance of the Desktop system are not
provided by Miyachi Europe Corporation. Cleaning and preventive checks however, could
identify possible problems.
Cleaning and preventive checks though could identify and prevent possible problems.
Table 7: Daily Maintenance
Item
Maintenance
Action
Fixture
- Clean and remove
dust from parts:
- Use damp cloth / compressed air
Thermode
- Remove
contamination:
- Check plan
parallelism:
- Thermode cleaning module 61W0002;
- Polishing disk 69C0000
Use pressure paper 67W0003 or
use low pressure paper; 67W0023
Control box
- Clean and remove
dust from parts
- Disconnect system from power supply;
- Use clean cloth (& tweezer).
Thermode head
- Clean and remove
dust from parts:
- Disconnect system from power supply;
- Use damp cloth
Power supply
- Clean and remove
dust from parts:
- Disconnect system from power supply;
- Use damp cloth
Emergency
control system
- Make sure the
complete system is
disconnected from
the power supply
- Press all emergency stop push buttons in
sequence.