11
D
ESK
T
OP
S
ERIES
–
AUTOMATIC OPERATION
2.6
SPECIFICATIONS – AIR AND ELECTRICAL SUPPLIES
General
Weight Joining system
40 kg / 88 lbs
Dimensions Joining system
Depth
Width
Height
System: Heat Source:
600 mm / 23.62 Inch Dependent on
550 mm / 21.65 Inch Unflow constant heat
510 mm / 20.04 Inch
Maximum fixture height
80 mm / 3.15 Inch
Gantry open width
520 mm / 20.47 Inch
Fixture assembly base plate
160x160 mm / 6.30x6.30 Inch
Starting operation
Two hand control
Operating temperature
15-40 °C / 60-104 °F
Operating humidity
93%@40 °C / 93%@104 °F
Connection requirements
Input voltage Uniflow
Main fuse
Input voltage Desktop (See note below)
Main fuse
230 Vac, 50 Hz, 1-Phase / earth / zero
16 A max, type C or D delay fuse
230 Vac, 50 Hz, 1-Phase / earth / zero (Europe)
4 A max, type C or D delay fuse
Compressed air required
6 bar, dry & filtered air
Machine data
Maximum peak current (Uniflow)
Peak power (Uniflow 2)
Maximum peak current (Desktop)
Peak power (Destktop)
Control voltage, internal
Control voltage, internal
16 A
3.5 kw
4 A
300 W
12 Vdc, supplied by the transformer (option)
24 Vdc, supplied by the transformer (option)
Optional
Customer’s choice
Note: Electrical supplies in non-European countries will be different.
Содержание DT-350