53
D
ESK
T
OP
S
ERIES
–
AUTOMATIC OPERATION
Uniflow time-out
Uniflow is not responding within #
seconds after start signal
Working fire-switch
Z-movement head
Wiring / connectors Uniflow
Uniflow alarm
Uniflow error
See Uniflow manual
HEAD:
ERROR
DESCRIPTION
CHECK
Time out head up Head must be in upper position within
# seconds
Air pressure
Sensors
Working slide
Time out head
down
Head must be in lower position within
# seconds
Air pressure
Sensors
Working slide
TURNTABLE:
ERROR
DESCRIPTION
CHECK
Time-out
turntable
Turntable must be in position within #
seconds
Air pressure
Sensors
Working turntable
Illegal sensor
state turntable
Sensors are activated simultaneously
Working position sensors
Fire while head
up
Technical fault firing switch or
manually activated the fire switch while
head is home
Fire switch
KAPTON TAPE MODULE:
ERROR
DESCRIPTION
CHECK
Time out Kapton
Kapton tape must be in position within
# seconds.
Air pressure
Working Kapton tape module