16
D
ESK
T
OP
S
ERIES
–
AUTOMATIC OPERATION
D.
Fan outlet
E.
Main switch
F.
Mains input connection
G.
Serial number and CE plate
H.
J6B Z-axis valve/cool valve
J. J6A relays
Note: The connections may not be the same as shown.
3.2
TAPE INTERPOSER MODULE
If this is installed, refer to the applicable manual.
3.3
ACF MODULE
If this is installed, refer to the applicable manual.
3.4
SAFETY MEASURES AND DEVICES
For a list of the system pictograms, refer to table 1 of this manual. Make sure you obey the
warning and caution instructions in this table.
3.4.1
Protection guards
The two-hand control is designed in such a way that the operator is protected from crushing
and burning. It also prevents the unintended starting of the bonding process. When the head is
moving down or the turntable is moving, there is a danger of crush injuries.
3.4.2
Hot parts
If the thermode is touched there is a danger of burn injuries as the temperature of the
thermode can rise to 600 deg C. The thermode area has an optional shield and a warning
pictogram is placed on the head guard.
3.4.3
Electrical safety
The Desktop system using pulsed heat is not provided with a main switch. The system power
is controlled by the Uniflow. The Desktop system using constant heat control has no mains
switch and before work is done, the complete desktop must be disconnected from the main
supplies.
3.4.4
Emergency stop
The Desktop system is equipped with one emergency stop push button which is mounted on
the front of the machine. Activation of the emergency stop button will stop all machine
movements, but if the bond head is in the down position it well rise. Additionally, the main
supply must be disconnected to isolate the constant heat controller.