ISQ20
Commissioning
76609605EN-ISQ20-V1.2.docx 43/63
5.4
Insulation Test
We use power supply filters in our units to meet European EMC regulations. These filters
have a discharge resistance to earth in each phase which is illustrated below. The
resistance value is 1 M
in each case. This results in an effective resistance of 333 k
for a cumulative insulation resistance measurement (L1-L2-L3 to earth).
Abb. 11: Circuit structure for mains filter
We recommend disconnecting the unit for measuring insulation resistances of a system,
as this will enable an insulation test under even this technical restriction.
5.5 Switching-on
Crushing Hazard!
During switching on the welding head can move.
Ensure that a safe distance is maintained to the welding head.
Plant set-up should only be carried out by qualified personnel and with extreme care.
Fundamental functions of the controller can be protected with a PIN, which should be
fixed by the set-up personnel.
Caution
For switching-on turn the main switch from „0“ to „1“.
Status display “01” indicates that the unit is “Ready”.
L1
L1
L1
L1’
L2
L1
R
R
R
R
C3 R
C3
C1
C1
C1
R
C3
C2 C2 C2
L2’
L3
L3’
PE
PE
Mains
each with 1 MOhm
Device
Содержание Amada ISQ20 Series
Страница 7: ...ISQ20 General Information 76609605EN ISQ20 V1 2 docx 7 63 1 3 Declaration of Conformity...
Страница 52: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 52 63 8 3 AWS3 pneumatic 1 Head...
Страница 53: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 53 63 8 4 AWS3 pneumatic 2 Head...
Страница 54: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 54 63 8 5 AWS3 pneumatic with Profibus...
Страница 55: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 55 63 8 6 AWS3 pneumatic with Ethernet IP...
Страница 56: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 56 63 8 7 AWS3 motorized 1 Head...
Страница 57: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 57 63 8 8 AWS3 motorized 2 Head...
Страница 58: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 58 63 8 9 AWS3 motorized 1 Head with Profibus...
Страница 59: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 59 63 8 10 AWS3 motorized 1 Head with Ethernet IP...
Страница 61: ...ISQ20 Connection Schemes 76609605EN ISQ20 V1 2 docx 61 63 9 Connection Schemes 9 1 Binary Connections 1...
Страница 62: ...ISQ20 Connection Schemes 76609605EN ISQ20 V1 2 docx 62 63 9 2 Binary Connections 2...