ISQ20
Connections
76609605EN-ISQ20-V1.2.docx 32/63
4.3.4 X4:
Valves
DSUB 15 - socket
Pin
I/O
Function
Note
X4.1
O15
VV1
Valve triggering 1 +24 V
Function depends on control mode, see
chap. 5.3.1
X4.2
VV1_GND
0 V ext. (ref. to 24 V)
X4.3
VV1_PE
Protective
earth
X4.4
O16
VV2
Valve triggering 2, +24 V
Function depends on control mode, see
chap. 5.3.1
X4.5
VV2_GND
0 V ext. (ref. to 24 V)
X4.6
VV2_PE
Protective
earth
X4.7
O17
VV3
Valve triggering 3, +24 V
Function depends on control mode, see
chap. 5.3.1
X4.8
VV3_GND
0 V ext. (ref. to 24 V)
X4.9
VV3_PE
Protective
earth
X4.10
O18
VV4
Valve triggering 4, +24 V
Function depends on control mode, see
chap. 5.3.1
X4.11
VV4_GND
0 V ext. (ref. to 24 V)
X4.12
VV4_PE
Protective
earth
X4.13
O19
VV5
Valve triggering 5, +24 V
The valve output can be chronologically
programmed.
On current changeover the valve comes
after the first current program and remains
until end of second hold time.
X4.14
VV5_GND
0 V ext. (ref. to 24 V)
X4.15
VV5_PE
Protective
earth
4.3.5 X5:
Start
Binder 6 + PE - socket
Pin
I/O
Function
Note
X5.1
+24 V
External supply voltage
X5.2
I15 Start
head 1+2
min. 35 mA at 24 V
Unit has to be “ready” before start is set
(i.e. Quick Stop is set and unit is in a
welding menu).
A program has to be selected in case of
external program selection (not program
“0”).
For a sequential program (e. g. lower
stroke cylinder), the cylinder initiators
have to be in basic position.
This input is used for automatic sequential
run in twin-head mode (parallel with
current changeover or consecutive
sequence):
head 1 –head 2 - FK – end.
Setting this input starts welding.
X5.3
I16 Start
head 1
min. 35 mA at 24 V
Start signal for head 1 in twin head mode.
X5.4
I17 Start
head 2
min. 35 mA at 24 V
Start signal for head 2 in twin head mode.
X5.5
0 V ext.
(ref. to 24 V)
X5.PE
PE Protective
earth
Содержание Amada ISQ20 Series
Страница 7: ...ISQ20 General Information 76609605EN ISQ20 V1 2 docx 7 63 1 3 Declaration of Conformity...
Страница 52: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 52 63 8 3 AWS3 pneumatic 1 Head...
Страница 53: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 53 63 8 4 AWS3 pneumatic 2 Head...
Страница 54: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 54 63 8 5 AWS3 pneumatic with Profibus...
Страница 55: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 55 63 8 6 AWS3 pneumatic with Ethernet IP...
Страница 56: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 56 63 8 7 AWS3 motorized 1 Head...
Страница 57: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 57 63 8 8 AWS3 motorized 2 Head...
Страница 58: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 58 63 8 9 AWS3 motorized 1 Head with Profibus...
Страница 59: ...ISQ20 Connection Variants Examples 76609605EN ISQ20 V1 2 docx 59 63 8 10 AWS3 motorized 1 Head with Ethernet IP...
Страница 61: ...ISQ20 Connection Schemes 76609605EN ISQ20 V1 2 docx 61 63 9 Connection Schemes 9 1 Binary Connections 1...
Страница 62: ...ISQ20 Connection Schemes 76609605EN ISQ20 V1 2 docx 62 63 9 2 Binary Connections 2...