 Warning:

• The unit must not be installed by the user. Ask a dealer or an authorized 

technician to install the unit. If the unit is installed incorrectly, water leakage, 
electric shock, or 

fi

 re may result.

•  For installation work, follow the instructions in the Installation Manual and use 

tools and pipe components speci

fi

 cally made for use with R410A refrigerant. 

The R410A refrigerant in the HFC system is pressurized 1.6 times the pressure 
of usual refrigerants. If pipe components not designed for R410A refrigerant are 
used and the unit is not installed correctly, the pipes may burst and cause dam-
age or injuries. In addition, water leakage, electric shock, or 

fi

 re may result.

•  The unit must be installed according to the instructions in order to minimize 

the risk of damage from earthquakes, typhoons, or strong winds. An incor-
rectly installed unit may fall down and cause damage or injuries.

•  The unit must be securely installed on a structure that can sustain its weight. 

If the unit is mounted on an unstable structure, it may fall down and cause 
damage or injuries.

•  If the air conditioner is installed in a small room, measures must be taken to 

prevent the refrigerant concentration in the room from exceeding the safety 
limit in the event of refrigerant leakage. Consult a dealer regarding the appro-
priate measures to prevent the allowable concentration from being exceeded. 
Should the refrigerant leak and cause the concentration limit to be exceeded, 
hazards due to lack of oxygen in the room may result.

•  Ventilate the room if refrigerant leaks during operation. If refrigerant comes 

into contact with a 

fl

 ame, poisonous gases will be released.

•  All electric work must be performed by a quali

fi

 ed technician according to 

local regulations and the instructions given in this manual. The units must be 
powered by dedicated power lines and the correct voltage and circuit breakers 
must be used. Power lines with insuf

fi

 cient capacity or incorrect electrical 

work may result in electric shock or 

fi

 re.

•  Use C1220 copper phosphorus, for copper and copper alloy seamless pipes, 

to connect the refrigerant pipes. If the pipes are not connected correctly, the 
unit will not be properly grounded and electric shock may result.

•  Use only speci

fi

 ed cables for wiring. The wiring connections must be made 

securely with no tension applied on the terminal connections. Also, never 
splice the cables for wiring (unless otherwise indicated in this document).

  Failure to observe these instructions may result in overheating or a 

fi

 re.

•  The terminal block cover panel of the outdoor unit must be 

fi

 rmly attached. If 

the cover panel is mounted incorrectly and dust and moisture enter the unit, 
electric shock or 

fi

 re may result.

•  When installing or relocating, or servicing the air conditioner, use only the 

speci

fi

 ed refrigerant (R410A) to charge the refrigerant lines. Do not mix it with 

any other refrigerant and do not allow air to remain in the lines.

  If air is mixed with the refrigerant, then it can be the cause of abnormal high 

pressure in the refrigerant line, and may result in an explosion and other 
hazards.

  The use of any refrigerant other than that speci

fi

 ed for the system will cause 

mechanical failure or system malfunction or unit breakdown. In the worst case, 
this could lead to a serious impediment to securing product safety.

•  Use only accessories authorized by Mitsubishi Electric and ask a dealer or an 

authorized technician to install them. If accessories are incorrectly installed, 
water leakage, electric shock, or 

fi

 re may result.

•  Do not alter the unit. Consult a dealer for repairs. If alterations or repairs are 

not performed correctly, water leakage, electric shock, or 

fi

 re may result.

•  The user should never attempt to repair the unit or transfer it to another loca-

tion. If the unit is installed incorrectly, water leakage, electric shock, or 

fi

 re 

may result. If the air conditioner must be repaired or moved, ask a dealer or 
an authorized technician.

•  After installation has been completed, check for refrigerant leaks. If refriger-

ant leaks into the room and comes into contact with the 

fl

 ame of a heater or 

portable cooking range, poisonous gases will be released.

1. Safety precautions

 Before installing the unit, make sure you read all the “Safety precau-

tions”.

  Please report to or take consent by the supply authority before connec-

tion to the system.

  Equipment complying with IEC/EN 61000-3-12

 Warning:

Describes precautions that must be observed to prevent danger of injury or 
death to the user.

 Caution:

Describes precautions that must be observed to prevent damage to the unit.

After installation work has been completed, explain the “Safety Precautions,” use, and 
maintenance of the unit to the customer according to the information in the Operation 
Manual and perform the test run to ensure normal operation. Both the Installation 
Manual and Operation Manual must be given to the user for keeping. These manuals 
must be passed on to subsequent users.

 : Indicates a part which must be grounded.

 Warning:

Carefully read the labels af

fi

 xed to the main unit.

Con

fi

 rmation of parts attached

In addition to this manual, the following parts are supplied with the outdoor unit.
They are used for grounding the S terminals of transmission terminal blocks TB3, 
TB7. For details refer to “6. Electrical work”.

Grounding lead wire (

×

 2)

Note: This symbol mark is for EU countries only.
 

 This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV, and/or to the directive 
2006/66/EC Article 20 Information for end-users and Annex II.

Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused.
This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, should be disposed of separately from your 
household waste.
If a chemical symbol is printed beneath the symbol (Fig.1) , the chemical symbol means that the battery or accumulator contains a heavy metal at a certain 
concentration. This will be indicated as follows:
Hg: mercury (0,0005%), Cd: cadmium (0,002%), Pb: lead (0,004%)
In the European Union there are separate collection systems for used electrical and electronic products, batteries and accumulators.
Please, dispose of the equipment, batteries and accumulators correctly at your local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!

 Caution:

•  Do not vent R410A into the Atmosphere:
•  R410A is a Fluorinated Greenhouse gas, covered by the Kyoto Protocol, with a Global Warming Potential  (GWP)=1975.

Contents

1. Safety 

precautions 

..................................................................................... 2

2. Installation 

location 

.................................................................................... 4

3.  Installing the outdoor unit .......................................................................... 6
4.  Installing the refrigerant piping .................................................................. 6

5. Drainage 

piping 

work 

................................................................................. 9

6. Electrical 

work 

........................................................................................... 9

7. Test 

run 

....................................................................................................12

Fig. 1

Содержание PUMY-P125

Страница 1: ...ir Conditioners PUMY P125 140VHMS PUMY P125 140YHMS INSTALLATION MANUAL For safe and correct use read this manual and the indoor unit installation manual thoroughly before installing the air condition...

Страница 2: ...ent to securing product safety Use only accessories authorized by Mitsubishi Electric and ask a dealer or an authorized technician to install them If accessories are incorrectly installed water leakag...

Страница 3: ...refrigeration oil oil deterioration may result Do not use refrigerant other than R410A refrigerant If another refrigerant is used the chlorine will cause the oil to deteriorate Use the following tool...

Страница 4: ...portation handles of the outdoor unit to transport the unit If the unit is carried from the bottom hands or fingers may be pinched 2 3 Outline dimensions Outdoor unit Fig 2 1 Constraints on indoor uni...

Страница 5: ...ir outlet guides for upward airflow 2 4 2 When installing multiple outdoor units Leave 10 mm space or more between the units 1 Obstacles at rear only Fig 2 8 2 Obstacles at rear and above only Fig 2 9...

Страница 6: ...it may fall down and cause damage or injuries The unit must be installed according to the instructions in order to minimize the risk of damage from earthquakes typhoons or strong winds An incor rectly...

Страница 7: ...ak them Bend radius of 100 mm to 150 mm is sufficient Make sure the pipes do not contact the compressor Abnormal noise or vibration may result 1 Pipes must be connected starting from the indoor unit F...

Страница 8: ...re does not decrease 2 Pressurize to 1 5 MPa 15 kgf cm2 G wait five minutes and make sure the pressure does not decrease 3 Pressurize to 4 15 MPa 41 5 kgf cm2 G and measure the surrounding tem peratur...

Страница 9: ...electrical part box of indoor and outdoor units because the box is sometimes removed at the time of service work 5 Never connect the main power source to terminal block of transmission line If connect...

Страница 10: ...50 M NET R C Main 101 to 150 Set at an IC Main address within the same group plus 100 M NET R C Sub 151 to 200 Set at an IC Main address within the same group plus 150 MA R C Unnecessary address sett...

Страница 11: ...S TB3 M1M2 S M1M2 S A B M1M2 M1M2 S M1M2 S F A B C E D TB7 IC 51 TB15 TB15 TB15 MA 01 IC TB5 03 IC TB5 TB5 02 IC TB5 04 IC 05 IC 07 IC 06 L1 MA MA MA OC 53 OC 1 m4 3 Power Supply Unit L3 L 7 L4 m 3 1...

Страница 12: ...fuse with correct capacity Using fuse and wire or copper wire with too large capacity may cause a malfunction of unit or fire IMPORTANT Make sure that the current leakage breaker is one compatible wit...

Страница 13: ...or the compressor will start to warm up after power is supplied After supplying power for the times indicated below measure the insulation resistance again The insulation resistance drops due to accum...

Страница 14: ......

Страница 15: ......

Страница 16: ...BH79D109H05 Printed in Japan Please be sure to put the contact address telephone number on this manual before handing it to the customer...

Отзывы: