background image

Ceiling Recessed Type, 2-Way Air Direction (FDTW)

1. Push one side of the inlet panel (pin A side) upward.

2. Disengage the panel from pin A

3. Disengage the panel from the pin B and remove the panel.

4. Press the knobs of the air filter inward, remove the

hook area from the air conditioner unit, and remove
the air filter.

HOW TO MAINTAIN THE AIR CONDITIONING SYSTEM

Ceiling Recessed Type (FDT)

1. Hold the notches (in two

places on the left and right
sides) of the inlet grill and
pull the inlet grill down-
ward, opening it.

2. Pinch the hook parts (in

two places on the left and
right sides) at the bottom of
the filter as shown in the
figure below and pull the
filter forward while pushing
it upward slightly.

Cleaning the Air Filter

Clean the air filter regularly to perform cooling and heating operations in the most efficient and economical manner.

 Caution: 

Make sure to stop the operation and turn the power supply switch off when you clean the air filter.

The fan inside rotates at high speeds, leading to injury.

 Caution: 

Fix the steps securely if you use them to install or remove the air filter.

The air conditioning system may fall down or overturn, leading to injury.

How to Remove the Air Filter (other than types whose panels automatically move up/down to make filter cleaning easier)

Remove the air filter according to the procedure for each type.

 CAUTION

Do not dry the filter under direct sunlight or using fire. The filter will be damaged.

Do not operate the air conditioning system while the air filter is removed. The air
conditioning system may be damaged.

At the End of the Season

Make sure to turn the power supply switch off.

The air conditioning system consumes several tens of watts of electricity even when it is stopped.

Clean the air filter and mount it.

Clean the indoor and outdoor units to remove any dirt.

Maintenance of the Unit

Clean the unit by wiping it with a piece of soft and dry cloth. If the unit is very dirty, wipe it with a piece of cloth wet with neutral
detergent dissolved in lukewarm water and wipe it off with a piece of cloth soaked in clean water.

At the Start of the Season

Make sure that there is no object blocking the airflow around the inlet and outlet openings of the indoor and outdoor units.

Inspect the air filter. If it is dirty, clean and mount it.

Turn the power supply switch on 12 hours before starting the operation.

Filter

Hooks

1

 Push the pin A side upward.

2

 Disengage the pin A side.

3

 Disengage the pin B side.

Pin A

Panel

Knobs

Hook

Air filter

Air conditioner unit

Ceiling Recessed Cassetteria Type (FDR)

1. Push the inlet panel upward.

2. Pull the inlet panel outward. When the inlet panel is

disengaged from the pins, it can be opened by
swinging it downward.

3. Rotate the hooks and disengage the corrugated

filter from the hooks.

4. Slide the flat filter toward the center and remove it.

Flat filter

Hook

Corrugated filter

Ceiling Recessed Type, 1-Way Air Direction (FDTS)

1. Slide the lever of the inlet grill in the direction of the

arrow (

) direction and open the grill by swinging it

downward.

2. Push the air filter backward to disengage the front

hook area, then slide the filter forward and remove
it.

Remove by sliding forward.

Front side

Insulation

Push backward.

Air filter

Ceiling Suspended Type (FDE)

1. Slide the lever of the inlet grill in the direction of the

arrow (

) and open the grill by swinging it down-

ward.

2. While light pushing up, remove the filter from the tabs

at the left and right, and pull towards the front.

High Static Pressure Duct Type (FDU)
Middle Static Pressure Duct Type (FDUM) (FDQM)
Ceiling mounted duct type (FDUR)
Ultra thin ducted Type (FDQS)

The air filter is mounted at the installation of the air
conditioning system. Please obtain explanations on how
to remove and clean the filter from the dealer from whom
you purchased the air conditioning system.

Floor Standing, Lowboy Type (Exposed Type) (FDFL)

Remove the front panel and pull the air filter out from the
bottom of the unit.

Floor Standing, Lowboy Type (Concealed Type)
(FDFU)

Pull the air filter out from the bottom of the unit.

How to Clean the Filter

1. Clean the filter under running water. If the filter is not very dirty, you can clean it by lightly dusting it off or by using cleaner.

If it is very dirty, dissolve some neutral detergent in lukewarm water (approximately 30 °C), rinse the filter with it, and wash
the detergent away from the filter completely.

2. Dry the air filter and mount it in the unit, then press the filter reset switch.

In the case of unit types whose panels automatically move up/down to make filter cleaning easier, the filter is automatically
set in place by operating the GRILL switch.

15

Pin B

Knobs

PULL

Inner panel frame

Outer panel frame

pin

2. While light pushing up, remove the filter from the tabs

at the left and right, and pull towards the front.

Tab

FDTQ Series

1. Slide the lever of the suction grille in the arrow (

)

direction to open the grille.

Wall mount type (FDK)

1. Pull up the suction grill forward.

Hold the concave sections at both the right and left
side with your hands and pull the suction grill forward.
It stops while being open at about 60

°

.

2. Lightly hold the handle of the air filter, slightly lift it

upward, and then pull it out forward.

Air filter

Tab

Suction grille

Air filter

Tab

Suction grille

Tab

Ceiling Recessed Type (FDTC)

1. Slide the inlet grill levers in the

direction of the arrow (

), and

open it downwards.

2. Turn the inlet grill stopper.

3. Pull the filter toward you.

4. When the filter is put in place,

insert the filter into the hooks
on the inlet grill, and be sure to
return the stopper to its original
position.

5. When putting the inlet grill back in

place, slide the levers in the opposite
direction and check to be sure that
the grill does not come open.

Hooks

Hooks

Stopper

PCA012A001L_E_P15

07.3.13, 11:13

15

Содержание MULTI-SERIES

Страница 1: ...Este acondicionador de aire cumple con la directiva EMC 89 336 EEC 92 31 EEC 93 68 EEC LV Directiva 73 23 EEC La indicaci n CE s lo corresponde al rea de suministro el ctrico de 50 Hz Este aparelho d...

Страница 2: ...ay occur SAFETY PRECAUTIONS CAUTION or your purchase of this package air conditioning system made dustries Please read through this manual before using the prod t appropriately according to the instru...

Страница 3: ...speeds leading to injury Make sure that the installation founda tion etc is not damaged due to long term use If it is left under damaged conditions the unit may fall down causing injury Do not wash th...

Страница 4: ...ion Middle At cooling dehumidifying operation Horizontal At heating operation Downward Page 14 5 4 3 Setting temperature Fan speed mode Operation mode 1 Press the MODE switch The range of operation mo...

Страница 5: ...lected at the same time SELECTING TIMER MODES Press the or switch If you press the switch the display of the following timer modes is switched in the downward direction Adjust the current time Turn of...

Страница 6: ...to the timer mode selection screen as shown below Step 2 If set to turn off after 10 hours lit lit for 2 seconds lit lit After the setting the remaining time is displayed in decre ments of 1 hour as t...

Страница 7: ...u press the RESET switch the remote controller will return to one screen earlier Press the SET switch The remote controller goes into the ON timer mode Example flashes and turns on Press the or switch...

Страница 8: ...tch the display of the timer modes is switched in the upward direction Select one of the modes Note If you press the RESET switch the remote controller will return to one screen earlier and display St...

Страница 9: ...the number changes from flashing to lit or is displayed The settings made so far are committed and the display changes as shown to the left Press the or switch If you press the switch is displayed If...

Страница 10: ...witch If you have selected is displayed Repeat step 4 and onward on page 8 If you have selected is displayed Repeat step 2 and onward on page 8 If you have selected the remote control ler exits from t...

Страница 11: ...he switch once This completely ends the noliday setting procedure Press the SET switch The display of turns off and the following is displayed After the holiday setting has been canceled the remote co...

Страница 12: ...ir setting numbers Press the switch to display settings starting from Sunday in order from the smallest setting number Press the switch to display the settings in the reverse order Select the day of t...

Страница 13: ...s the RESET switch to return to the display step 4 5 If or was selected If was selected Perform the following operation to cancel settings for all the days of the week See Canceling Weekly Timer Mode...

Страница 14: ...play At the on time At the off time If you press the switch while in the Silent setting mode the remote controller exits from the Silent setting mode and returns to the original display Please be awar...

Страница 15: ...Adjust the airflow direction properly Do not subject your skin to the airflow from the air conditioning system for prolonged periods of time Protect small animals and plants from such direct airflow a...

Страница 16: ...pen the grill by swinging it downward 2 Push the air filter backward to disengage the front hook area then slide the filter forward and remove it Remove by sliding forward Front side Insulation Push b...

Страница 17: ...switch was turned on The setting temperature cannot be changed the setting temperature display flashes The airflow becomes weak if the operation mode is changed during operation in the case of the hea...

Страница 18: ...aches the set number of hours in order to notify that the air filter should be cleaned Clean the air filter Page 15 The filter cleaning message is displayed in the display area It is displayed for 1 s...

Страница 19: ...rned on Moreover the outdoor unit will start operating approximately wer supply switch on INSTALLATION LOCATION ABOUT INSTALLATION MOVING AND INSPECTION MAINTENANCE Please observe the following points...

Страница 20: ...EC1N 2HA ENGLAND Phone 44 0 20 7842 8171 Fax 44 0 20 7842 8104 MITSUBISHI HEAVY INDUSTRIES AUSTRALIA PTY LTD 81 Railway Street Rockdale NSW 2216 Australia Phone 61 0 2 9597 7977 Fax 61 0 2 9597 7304 M...

Отзывы: