background image

Press the “ 

 LOUVER” switch at the position

you want to stop/fix the louver.

The display stops and the following is displayed, then the
swing louver is stopped and fixed.

(If fixed at position 1)

Press the “ 

 LOUVER” switch while the air con-

ditioning system is operating and the swing louver is

stopped.

The swing louver moves up and down continuously and
“ 

 ” is displayed for 3 seconds.

To Fix the Position of the Swing Louver

Press the “ 

 LOUVER” switch once while the swing

louver is moving.
The four available directions in which the swing louver can be
positioned are displayed for 2 seconds each in the order
shown left.

2

1

1

AIRFLOW ADJUSTMENT BY THE LOUVER SWITCH
 (FOR INDOOR UNITS WITH THE AUTO SWING FUNCTION)

HOW TO ADJUST THE AIRFLOW DIRECTION

To Move the Swing Louver

To Fix the Position of the Swing Louver

Recommended Louver Fix Positions

If you want to fix the louver at this
position, make sure to turn the
vertical louver to the left or right (in
the case of FDE).

Cool/Dry

Heat

14

USING THE AIR CONDITIONING SYSTEM IN A COMFORTABLE MANNER

Clean the filer frequently.

 Page18

If the filter is clogged...

The cooling/heating efficiency becomes lower. Moreover, electricity is wasted and the operation makes more noise.

A clogged filter may cause failures.

Dew may form and drop during the cooling operation.

Do not block the inlet and outlet
openings of the indoor and outdoor
units

Excessive force must not be applied to the air

conditioning system; doing so may lead to fail-

ure.

Set a moderate room temperature

Too much cooling or heating is not good for your

health. It is also a waste of electricity.

Block direct sunlight and prevent draft

Block direct sunlight with window blinds and curtains

at cooling. Close the windows and doors except when

ventilation is necessary.

The filter should be cleaned

whenever the “FILTER

CLEANING” message is

displayed, as well as at the end

of cooling and heating seasons.

Adjust the airflow direction properly

Do not subject your skin to the airflow from the

air conditioning system for prolonged periods

of time. Protect small animals and plants from

such direct airflow as well.

If your feet feel cold at heating

If the ceiling is high and the warm airflow does

not circulate down to your floor area suffi-

ciently, it is recommended to use a circulation

fan. Consult the dealer for the details.

Stop the operation and turn the
power supply off if there are any
possibilities of lightning strikes
during a thunderstorm

Failure to do so may lead to failure of the air

conditioning system.

When “ 

 ” (PREPARATION OF HEATING ) is displayed,

the swing louver is automatically set at the horizontal position.
When heater preparation is completed and the air conditioning system is
switched to normal operation, the position of the swing louver returns to
the set position.

REQUEST

Horizontal position

The swing louver may be broken if you attempt to move it forcefully with your hands. Do not attempt to move it with your hands.

Do not direct the airflow downward for extended periods of time at cooling operation. Dew may form on the side panel and drop
from it (in the case of FDE).

1

VENTILATION MODE OPERATION (WHEN A VENTILATOR IS INSTALLED)

NON-LINKED VENTILATION OPERATION

LINKED VENTILATION OPERATION

NOTE

If no ventilator is connected, nothing will happen when the ventilation switch is pressed. ("Operation invalid" is displayed.)

NOTE

Operation is invalid even if the ventilation switch is pressed.

When the ventilator is set to "NO VENTI LINK" (Ventilation not linked), the ventilator can be set to ON/OFF
by itself, without regard to the operation or stopping of the air conditioner. When the ventilator is set to
"VENTI LINK SET" (Ventilation linked), the ventilator will operate when the air conditioner operates.

Press the “ 

 VENTI” switch.

“ 

 ” is displayed, and ventilation operation begins.

1

Press the “ 

 ” switch.

If a ventilator is connected, ventilation will operate automati-

cally. “ 

 ” is displayed.

1

Stop

Stop

Press the “ 

 VENTI” switch a second

time.

Press the “ 

 ” switch a scond time.

PCA012A001H_E_P14

05.11.16, 12:22

14

Содержание MULTI-SERIES

Страница 1: ...Este acondicionador de aire cumple con la directiva EMC 89 336 EEC 92 31 EEC 93 68 EEC LV Directiva 73 23 EEC La indicaci n CE s lo corresponde al rea de suministro el ctrico de 50 Hz Este aparelho d...

Страница 2: ...ay occur SAFETY PRECAUTIONS CAUTION or your purchase of this package air conditioning system made dustries Please read through this manual before using the prod t appropriately according to the instru...

Страница 3: ...speeds leading to injury Make sure that the installation founda tion etc is not damaged due to long term use If it is left under damaged conditions the unit may fall down causing injury Do not wash th...

Страница 4: ...ion Middle At cooling dehumidifying operation Horizontal At heating operation Downward Page 14 5 4 3 Setting temperature Fan speed mode Operation mode 1 Press the MODE switch The range of operation mo...

Страница 5: ...lected at the same time SELECTING TIMER MODES Press the or switch If you press the switch the display of the following timer modes is switched in the downward direction Adjust the current time Turn of...

Страница 6: ...to the timer mode selection screen as shown below Step 2 If set to turn off after 10 hours lit lit for 2 seconds lit lit After the setting the remaining time is displayed in decre ments of 1 hour as t...

Страница 7: ...u press the RESET switch the remote controller will return to one screen earlier Press the SET switch The remote controller goes into the ON timer mode Example flashes and turns on Press the or switch...

Страница 8: ...tch the display of the timer modes is switched in the upward direction Select one of the modes Note If you press the RESET switch the remote controller will return to one screen earlier and display St...

Страница 9: ...the number changes from flashing to lit or is displayed The settings made so far are committed and the display changes as shown to the left Press the or switch If you press the switch is displayed If...

Страница 10: ...witch If you have selected is displayed Repeat step 4 and onward on page 8 If you have selected is displayed Repeat step 2 and onward on page 8 If you have selected the remote control ler exits from t...

Страница 11: ...he switch once This completely ends the noliday setting procedure Press the SET switch The display of turns off and the following is displayed After the holiday setting has been canceled the remote co...

Страница 12: ...ir setting numbers Press the switch to display settings starting from Sunday in order from the smallest setting number Press the switch to display the settings in the reverse order Select the day of t...

Страница 13: ...s the RESET switch to return to the display step 4 5 If or was selected If was selected Perform the following operation to cancel settings for all the days of the week See Canceling Weekly Timer Mode...

Страница 14: ...play At the on time At the off time If you press the switch while in the Silent setting mode the remote controller exits from the Silent setting mode and returns to the original display Please be awar...

Страница 15: ...Adjust the airflow direction properly Do not subject your skin to the airflow from the air conditioning system for prolonged periods of time Protect small animals and plants from such direct airflow a...

Страница 16: ...pen the grill by swinging it downward 2 Push the air filter backward to disengage the front hook area then slide the filter forward and remove it Remove by sliding forward Front side Insulation Push b...

Страница 17: ...switch was turned on The setting temperature cannot be changed the setting temperature display flashes The airflow becomes weak if the operation mode is changed during operation in the case of the hea...

Страница 18: ...aches the set number of hours in order to notify that the air filter should be cleaned Clean the air filter Page 15 The filter cleaning message is displayed in the display area It is displayed for 1 s...

Страница 19: ...rned on Moreover the outdoor unit will start operating approximately wer supply switch on INSTALLATION LOCATION ABOUT INSTALLATION MOVING AND INSPECTION MAINTENANCE Please observe the following points...

Страница 20: ...EC1N 2HA ENGLAND Phone 44 0 20 7842 8171 Fax 44 0 20 7842 8104 MITSUBISHI HEAVY INDUSTRIES AUSTRALIA PTY LTD 81 Railway Street Rockdale NSW 2216 Australia Phone 61 0 2 9597 7977 Fax 61 0 2 9597 7304 M...

Отзывы: