NAMES AND FUNCTIONS OF THE REMOTE CONTROLLER SWITCHES
The figure below shows the remote controller with the cover opened. Note that all the items that may be dis-
played in the liquid crystal display area are shown in the figure for the sake of explanation.
Characters displayed with dots in the liquid crystal display area are abbreviated.
Pull the cover downward to open it.
●
When you operate the air conditioning system at the start of the season or after it has been stopped for a prolonged
period,
turn the power switch on (ON) 12 hours before starting the air conditioning operation
in order to protect the
air conditioning system (the current is conducted into the crank case and warms the compressor). Do not turn the power
supply switch off during the season. (The current is conducted to the crank case heater while the compressor is stopped,
keeping the compressor warm and preventing failure of the compressor due to accumulation of liquid refrigerant.)
●
Do not turn the power supply switch off during the season.
Do not turn the power supply switch of an
unused indoor unit off either, keep it “ON.”
If the power supply to one of the indoor units in the same
system is turned off, water may leak from the indoor unit (drained water overflows).
●
Turn the power supply switch off during the off-season in order to save electricity. (If the power supply switch is kept turned on, current
continues to be conducted to the crank case heater and power is consumed even if the air conditioning system is not operated.)
HOW TO USE THE AIR CONDITIONING SYSTEM
Request:
Press the “
” switch.
The air conditioning system starts operating.
2
Press the Temperature setting switches.
Press the
or
switch to set the room temperature.
Press the “
” switch.
Stop
Guideline for room temperature setting
Cool ............................... 26 to 28°C
Dry ................................. 21 to 24°C
Heat ............................... 22 to 24°C
Fan ................................ Not necessary to set the room temperature
Press the “
FAN SPEED” switch.
The range of fan speed modes is displayed according to
the model of the indoor unit.
In case of 3-speed:
In case of 2-speed:
In case of 1-speed: The switch operation is disabled.
Press the “
LOUVER” switch.
If the indoor unit is equipped with the auto swing
function, the message “
” is
displayed when you press the “
LOUVER ”
switch, and the swing louver moves up and down.
If the indoor unit is not equipped with the auto swing function,
the message “
” is displayed.
●
Stopping the louver.
1. Press the switch once while the louver is moving to
display the stop positions in order.
2. Press the switch once again at the desired stop
position to stop the louver at that position.
Page 14
Effective stop position.
At automatic operation: Middle
At cooling/dehumidifying operation: Horizontal
At heating operation: Downward
Page 14
5
4
3
Setting temperature
Fan speed mode
Operation mode
1
Press the “
MODE” switch.
The range of operation modes is displayed according to the
model of the indoor unit.
Every time the switch is pressed, the display changes in the
order of “
(DRY)”
→
“
(COOL)”
→
“
(FAN)”
→
“
(HEAT)” and then “
(AUTO)”. (The automatic operation
can only be selected in case of the heating/cooling free
layout multi system KXR. The automatic operation cannot be
selected in case of KX.)
●
The settings of operation mode, temperature and air-
flow volume adjustment can be changed even when
the air conditioning system is stopped. When a switch
is pressed while the operation is stopped, the corre-
sponding display is turned on and you can change the
setting. The display turns on for three seconds after
changing the setting, then turns off automatically.
●
The display of “
” flashes
and the operation is switched to “Fan” in the following case
because the operation modes do not match.
(1) When other indoor units are operating in different modes
(with KXR, the heating/cooling free layout multi system, it
is possible to operate indoor units in different cooling/heat-
ing modes).
●
Do not turn the air conditioning system on/off frequently.
●
Do not use sharp objects to press the remote controller
switches.
3
HOW TO OPERATE THE AIR CONDITIONING SYSTEM
Weekly timer display
Displays the settings of
the weekly timer.
Operation/Stop switch
This switch is used to operate and
stop the air conditioning system.
Press the switch once to operate
the system and press it once again to
stop the system.
MODE switch
This switch is used to switch between
operation modes.
Operation setting display area
Displays setting temperature,
airflow volume, operation mode and
operation message.
Operation/Check indicator light
During operation: Lit in green
In case of error: Flashing in red
FAN SPEED switch
This switch is used to set the
airflow volume.
SET switch
This switch is used to apply the timer
operation setting.
See page 4 to 16.
This switch is also used to make silent
mode operation settings.
See page 13.
RESET switch
Press this switch while making settings
to go back to the previous operation.
See page 4 to 15.
This switch is also used to reset the
“FILTER CLEANING” message display.
(Press this switch after cleaning the air filter.)
Central control display
Displayed when the air conditioning
system is controlled by the option controller.
Timer operation display
Displays the settings related to
timer operation.
AIR CON No. (Air conditioning system No.) switch
Displays the number of the connected
air conditioning system.
CHECK switch
This switch is used at servicing.
TEST switch
This switch is used during test operation.
Temperature setting switches
These switches are used to set
the temperature of the room.
Timer setting switches
These switches are used to set
the timer mode and time.
See page 4 and 13.
TIMER switch
This switch is used to select
a timer mode.
See page 4.
GRILL switch
This switch has no function.
When this switch is pressed,
(Invalid Operation)
is displayed, but it does not mean a failure.
LOUVER switch
This switch is used to operate/stop
the swing louver.
See page 14.
VENT switch
This switch operates connected ventilators.
See page 14.
Ventilation display
Displays during ventilation operation.
See page 14.
5 4 2
1
3
DRY
COOL
FAN
HEAT
AUTO
Operation mode
PCA012A001J_E_P03
06.9.13, 14:31
3