Figure 7.1: User Parameter Rules
For 32DP-IF
Byte No.
0
1
*1
Bit 0 ~ Bit 7
Meaning
Not used (must be 0)
This byte is used for setting the Swap data, Swap parameter, Checking
I/O block status, and Special function block’s error status.
*1
Description
For first special function block
Byte No.
2
*3
3
4
5
Meaning
Type code of special
function block, lower
byte of BFM 30
*4
Type code of special
function block, higher
byte of BFM 30
*4
Total length m of
parameter data for
this special function
block.
Number (n) of BFM for
data exchange
*7
Description
m = 2 + n + 3
×
b
*6
First special function block
Byte No.
6
7
.....
5 + n
Meaning
First BFM address for
data exchange
*7
Second BFM address
for exchange
*7
....
n th BFM address for
exchange
*7
Description
First special function block
Byte No.
5 + n +1
5 + n + 2
5 + n + 3
××××
1
Bit 7
Bit 0 ~ 6
Meaning
Writing flag
BFM address
adjusted
*8
Lower byte of
parameter data
*8
Higher byte of
parameter data
*8
Description
If this BFM is
adjusted, this bit is ON
(1).
*8
First special function block
Byte No.
5 + n + 3
××××
1 +1
5 + n + 3
××××
1 + 2
5 + n + 3
××××
2
Bit 7
Bit 0 ~ 6
Meaning
Writing flag
BFM address
adjusted
*8
Lower byte of
parameter data
*8
Higher byte of
parameter data
*8
Description
If this BFM is
adjusted, this bit is ON
(1).
*8
For first special function block
For second special function block
Byte No.
.....
(5 + n + 3
××××
b)
*9
(5 + n + 3
××××
b)
+1
*10
.....
Meaning
.....
Higher byte of
parameter data
*8
Type code of special
function block, lower
byte of BFM 30
*4
.....
Description
Содержание FX2N-32DP-IF
Страница 4: ...FX2N 32DP IF Profibus DP Interface Unit ii...
Страница 6: ...FX2N 32DP IF Profibus DP Interface Unit iv...
Страница 12: ...FX2N 32DP IF Profibus DP Interface Unit x...
Страница 64: ...FX2N 32DP IF Profibus DP Interface Unit Address Setting 6 6 2 MEMO...
Страница 78: ...FX2N 32DP IF Profibus DP Interface Unit User Parameter 7 7 14 MEMO...
Страница 80: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostic Message 8 8 2 MEMO...
Страница 86: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostics 9 9 6 MEMO...
Страница 92: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 6 Figure A 6 Setting Global Parameter...
Страница 96: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 10 MEMO...
Страница 102: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 6 Figure B 6 Setting Global Parameter...
Страница 106: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 10 MEMO...
Страница 192: ...FX2N 32DP IF Profibus DP Interface Unit Appendix C C 86 MEMO...
Страница 194: ...FX2N 32DP IF Profibus DP Interface Unit Appendix D D 2 MEMO...
Страница 197: ......