FX2N-32DP-IF Profibus-DP Interface Unit
Appendix C:
C-68
C-2-31: FX
2N
-10PG (Motorola Format)
Requirements:
•
Cyclic data is 10 word inputs and 10 word output in every cycle.
•
Parameter is 78 bytes.
Table C-61: Cyclic Data of FX
2N
-10PG (Motorola Format)
Send Data
Receive Data
1st
Set the low word for target address
Ι
(BFM #13)
Low word for current address (BFM #24)
2nd
Set the upper word for target address
Ι
(BFM #14)
Upper word for current address (BFM #25)
3rd
Set the low word for operation speed
Ι
(BFM #15)
Low word for the target address
Ι
(BFM #13)
4th
Set the upper word for operation speed
Ι
(BFM #16)
Upper word for the target address
Ι
(BFM #14)
5th
Set the low word for the target address
ΙΙ
(BFM #17)
Low word for the target address
ΙΙ
(BFM #17)
6th
Set the upper word for the target address
ΙΙ
(BFM #18)
Upper word for the target address
ΙΙ
(BFM #18)
7th
Set the low word for operation speed
ΙΙ
(BFM #19)
Terminal information (BFM #38)
8th
Set the upper word for operation speed
ΙΙ
(BFM #20)
Status information (BFM #28)
9th
Set the operation pattern (BFM #27)
Error code (BFM #37)
10th
Set the operation command (BFM #26)
Operation command (BFM #26)
Table C-62: FX
2N
-10PG (Motorola Format)
Nr.
Parameter Name
Value Setting List
Description
00
(1st)
pulse rate lower
word
Default: 2000 (07D0 Hex)
Set the lower word for pulse rate.
(BFM #32)
Setting range (BFM #33, #32):
1 to 999999 (00000001 to
000F423F Hex)
01
(2nd)
pulse rate upper
word
Default: 0 (0000 Hex)
Set the upper word for pulse rate.
(BFM #33)
Setting range (BFM #33, #32):
1 to 999999 (00000001 to
000F423F Hex)
02
(3rd)
feed rate lower word Default: 2000 (07D0 Hex)
Set the lower word for feed rate.
(BFM #34)
Setting range (BFM #35, #34):
1 to 999999 (00000001 to
000F423F Hex)
Содержание FX2N-32DP-IF
Страница 4: ...FX2N 32DP IF Profibus DP Interface Unit ii...
Страница 6: ...FX2N 32DP IF Profibus DP Interface Unit iv...
Страница 12: ...FX2N 32DP IF Profibus DP Interface Unit x...
Страница 64: ...FX2N 32DP IF Profibus DP Interface Unit Address Setting 6 6 2 MEMO...
Страница 78: ...FX2N 32DP IF Profibus DP Interface Unit User Parameter 7 7 14 MEMO...
Страница 80: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostic Message 8 8 2 MEMO...
Страница 86: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostics 9 9 6 MEMO...
Страница 92: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 6 Figure A 6 Setting Global Parameter...
Страница 96: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 10 MEMO...
Страница 102: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 6 Figure B 6 Setting Global Parameter...
Страница 106: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 10 MEMO...
Страница 192: ...FX2N 32DP IF Profibus DP Interface Unit Appendix C C 86 MEMO...
Страница 194: ...FX2N 32DP IF Profibus DP Interface Unit Appendix D D 2 MEMO...
Страница 197: ......