Alarm
No.
Name
Description
Motion
(Note)
36
TE
TRANSFER
This alarm occurs if data
A
ERROR
fer does not go satisfactorily
(when FR-SFJ is connected to
CNC through bus line).
37 PE
PARAMETER
This alarm occurs if set
A
ERROR
meter value is out of the per-
missible range (this check is
made when the control system is
turned on).
40
TKCE
FR-TK
This alarm occurs if signal for
ECT ERROR
selection of FR-TK unit (when
FR-TK unit is used) is not input
properly.
41
TKTE
FR-TK
This alarm occurs if data
A
T R A N S F E R
ERROR
munication with FR-TK unit
(when FR-TK unit is used) does
not go properly.
45
OHP
OVER HEAT
This alarm occurs if ambient
A
(
AMP
.)
temperature is excessively high,
or main (power) circuit semi-
conductor overheats, due to
overload or stop of cooling fan.
46
OHM
OVERHEAT
This aiarm occurs if motor
A
OR
RESISTOR)
heats due to overload or stop of
motor cooling fan.
52
OD
ERROR
This alarm occurs if difference
A
EXCESS
(error) between referenced stop
position and true stop position
is excessively large (in posi-
tion control loop).
56
OA
OTHER AXIS
This alarm occurs if trouble
A
ALARM
curs with other servo control
axis (when FR-SFJ is connected
to CNC through bus line).
91
Содержание FREQROL-SFJ
Страница 14: ...c c c c FR SFJ Z 3 7K 0 0 3 0 KL 0 1l l c J I I L 4 Ii n 111 z n FR SFJ 5 5K 11...
Страница 67: ...2 To assemble per form step 1 in reverse order 64...
Страница 68: ...4...
Страница 70: ......
Страница 96: ...ting Motion C Only warning is displayed operation can be continued I i 93...