3.8.6
of oriented spindle stop function
Adjustment procedure
for encoder type oriented spin-
dle stop function)
Spindle stop position
Since there is no control means (potentiometer or ro-
tary switch) for stop position adjustment, stop posi-
tion should be adjusted by changing parameter setting
as described below.
With READY signal turned on, set
for parameter
and press
SET
switch.
0
After the spindle rotates
two revolutions and stops,
will be displayed by the 7-segment LED readout.
Press
or
switch to adjust stop position.
The spindle remains rotating while switch is held
down.
The spindle rotates about 1 deg. for each
100 of data value (one revolution for 4096 of data
value).
After the stop position has been determined, remove
dial gauge or other measuring device and press
switch.
After the completion of stop position adjustment,
turn off and on the power or press RESET switch to
reset.
When FR-SFJ is connected to M300 series CNC through
bus line,
the values set for parameters
and
should be also set for parameters
and
0RS2 appearing on the NC display screen ("Spindle
parameter", page 2).