3.3
FR-SFJ
status display and parameter settings
Operation status is displayed by the 7-segment LED readout
on card SFJ-CA1 and parameters can be set by DIP switches.
Status display and parameter settings depend on ROM version
of card SFJ-CA1 card.
For ROM version A@ . . . . .
(A) 3. 3. 1
For ROM version BO and thereafter . . . .
3. 3. 1
When FR-SFJ is connected to M300 CNC through bus line, sta-
tus can be displayed and parameter can be set on the NC CRT.
(For details,
refer to 3.5.)
DIP
switch settings and functions
Since
DIP
switch settings must be changed only when test op-
eration is required,
they should not be changed during normal
operation.
Mode
DIP switch setting
Function
Set position)
i
operation
i
1
2 3
Spindle parameters displayed by NC
CRT
are ignored.
When FR-SFJ is connected to M300 CNC,
the spindle parameters set and
played on the CNC side are ignored
and the parameters set on the FR-SFJ
side are used.
3
3
Setting prohibited (for manufacturer's
test operation)
4
1
2 3
Setting prohibited (for manufacturer's
15