2-2 Inspection
Clean the thennostat, place it in a hot-water tub, and
test it for thennostatic action by heating the tub to
raise the water temperature. The valve should start
opening at 76.5 ± 2
°
C (169.7 ± 3.6
°
F) and be fully
open at 90 ± 2
°
C (194 ± 3.6
°
F) with a valve lift of not
less than 9 mm (0.35 in.). A thennostat whose valve fails
to operate in this manner in the test must be replaced
with a new one.
3. Water pump
E
E
�
9
0
Temp
°
C
About 10
°
c
l18
°
FI
-----.in
Tl : Temperature (76.5
°
±
2
°
C (169.7
°
± 3.6
°
F)]
that makas valve start opening
T2 : Temperature (90
°
±
2
°
C (194
°
± 3.6
°
F)]
that makes valve fully open with a lift of
not less than 9 mm (0.35 in.I
Thermostat performance curve
The water pump is of centrifugal type. Its bearings are
,
·r
lubricated by engine oil fed from the main gallery
within the crankcase. The impeller is threadedly mounted
on the pump shaft.
@@
3-1 Disa�mbly
(1)
Remove pump cover (2)
by
loosening cover at
taching bolts (1 ).
(2)
Support the shaft with a stand to remove impel
ler (3).
[NOTE)
Impeller is threadedly mounted on shaft. The
thread is of right-hand screw.
1-Bolt
2-Cover
3-lmpeller
4-Unit seal
5-Snap ring
6-Bearing
7-Shaft
8-Bearing
9-Pump case