161
-
'10 • SR-T-091
(b) Wireless remote controller
* All displays are described in the liquid crystal display for explanation
Indication section
Operation section
Indicates set temperature.
Indicates the status of swing louver.
Indicates selected operation with .
Indicates for two seconds when FILTER
button is pressed.
Indicates when OFF-TIMER is set.
Indicates OFF-TIMER setting time. Indicates the
current time when the OFF-TIMER is not set.
When this is pressed once, the unit starts to
operate and when this is pressed once again,
it stops operating.
Used to swing the louver.
Every time this button is pressed, displays switch
as below.
Sets room temperature by pressing or button.
Sets time when setting the time.
Used to cancel the TIMER SETTINGS.
Used to reset the microcomputer.
Indicates the selected airflow volume
Indicates when ON-TIMER is set.
Indicates the ON-TIMER setting time.
Nothing displayed when ON-TIMER is
not set.
Sends signal to the air conditioner.
Every time this button is pressed, the mode is
switched as below.
Used to reset (turn off) the filter sign.
Press the button only after completing
the filter cleaning.
Sets ON TIMER operation.
Sets OFF TIMER operation.
Sets current time.
Содержание SRK60ZJX-S
Страница 85: ... 84 10 SR T 091 4 Ceiling cassette 4way compact type FDTC ...
Страница 89: ... 88 10 SR T 091 a PJA012D783 ...
Страница 189: ... 188 10 SR T 091 09 SRK DB 087D Service data record form 182 ...
Страница 197: ... 196 10 SR T 091 09 SRK DB 087D 11 Outdoor unit inspection points 20ZJX S 25ZJX S 35ZJX S 198 198 189 ...
Страница 267: ... 266 10 SR T 091 12 5 Super link E board SC ADNA E F SL2NA E and SL3N AE BE to control ...
Страница 268: ... 267 10 SR T 091 ...