For allowable temperature setting ranges, refer to the range setting of set temp.
■
Reference set temp
Cooling
…
26 to 28
°
C Dry
…
24 to 26
°
C Heating
…
20 to 24
°
C Fan
…
Setting temp is not required.
■
If the
Auto is selected for the set temp, the set temp display shows
“
0
”
. Temperature can be adjusted higher or lower with using
▲
▼
buttons. Note that
Auto is not displayed and
cannot be set when SC-SL2, SC-SL3, or SC-SL4 is connected.
■
If the
Back button is tapped without tapping the Set button, the selected set temp is invalidated and the display returns to the TOP screen.
Change flap direction
Menu
Direction
Cooling
16
:
14 (Mon)
F1: High power
Timer
Now stopping.
Set temp
F2: Energy-saving
Change flap direction
Ind. flap
Control
Back
4
Tap the desired flap direction. After
selecting the flap direction, the display
returns to the Select flap screen. (
�
1
)
5
When the 3D auto flow operation is
enabled, “3D AUTO” is displayed on
the Change flap direction button, as
shown on the left.
Menu
Direction
Auto
16
:
14 (Mon)
F1: High power
Timer
Now stopping.
Set temp
MEETING1
Room
3D AUTO
F2: Energy-saving
Select flap
Upper/lower flap
Back
Select the flap to change.
Left/right flap
3D AUTO
2
1
R/C
Room
Outdoor
3
■
When multiple IUs are connected to the remote control for a mixed environment consisting of FDKs with a left/right flap and IUs without a left/right flap, enabling the 3D auto flow operation will set the
models without a left/right flap to a flap position set before the 3D auto flow operation was started.
■
Since the flap is controlled automatically in the following operation, it may differ from the display on the R/C.
∙ When the room temperature is higher than the set temp (In case of the heating operation)
∙ When the
“
In operation for heating standby.
”
or
“
In operation for defrosting.
”
is displayed (In case of the heating operation).
Cool air is blown horizontally not to blow directly to human body.
∙ In a high humidity environment (during cooling operation)
■
When you select Auto swing while the Anti draft setting is enabled, the flap will not swing and be set at flap position 1 .
■
Changing the left/right flap direction and 3D auto flow operation cannot be performed from the SC-SL2, SC-SL3, or SC-SL4. Also note that 3D auto flow operation will not be disabled when you
change the flap direction from the SC-SL2, SC-SL3, or SC-SL4 during a 3D auto flow operation.
1
Tap the Change flap direction button on the TOP screen.
When an FDK with a left/right flap is not connected:
�
2
When one or more FDKs with a left/right flap are connected:
�
3
Change flap direction
Ind. flap
Control
Auto swing
Back
Outdoor
Room
R/C
Select the flap direction.
2
When the Change flap direction screen is displayed, tap the button of desired flap direction.
To swing the flap, tap the Auto swing button.
To fix the flap position, tap one of 1 to 4 buttons.
After selecting the flap direction,
When an FDK with a left/ right flap is not connected, the display returns to the TOP screen. (
�
1
)
When an FDK with a left/right flap is connected, the display returns to the Select flap screen. (
�
3
)
3
When one or more FDKs with a left/right flap are connected, the Select flap screen is displayed. Select the desired flap direction.
①
To change the up/down flap direction, tap the Upper/lower flap button. The Change flap direction screen for the up/down
flap is displayed. (
�
2
)
②
To change the left/right flap direction, tap the Left/right flap button. The Change flap direction screen for the left/right flap is
displayed. (
�
4
)
③
The 3D auto flow operation automatically controls the fan speed and flap direction to efficiently condition the air of the entire
room.
To switch to the 3D auto flow operation, tap 3D AUTO to enable the operation.
To disable the 3D auto flow operation, tap the 3D AUTO again. The flap direction returns to the direction that was set before
the 3D auto flow operation was enabled. The 3D auto flow operation will also be disabled when you change the up/down or left/
right flap direction during the 3D auto flow operation.
Note
�
Do not manually move the flaps or panel with anti draft by force. It could damage these flaps and panels.
�
Do not blow air downward for a long period of time during the cooling operation. Condensation may be generated and water may drip from the side panel. (In case of Ceiling suspended type)
�
For FDKs with a left/right flap, it is recommended that the flap should be set toward the right side when there is a wall on the left, or set toward the left side when there is a wall on the right. For more
information, refer to the Notes in the Individual flap control section.