When you press the F1 ( F2 ) switch, the operation mode, set temp, fan speed, flap direction registered to Favorite set 1 or
Favorite set 2 will be enabled.
■
Operation will start even if you press the
F1
(
F2
) switch while the unit is stopped.
■
You can change the operation mode, set temp, fan speed, flap direction after the operation has started with the favorite setting operation.
■
Following power on, the unit starts to operate initially with the following settings for both Favorite set 1 and Favorite set 2.
Operation mode
...Cooling
Set temp
...28°C
Fan speed
...3-speed
Flap direction
...Position 2
*
When an FDK with a left/right flap is connected
Left/right flap direction ...Center
3D AUTO
...Disabled
■
When Change set temp, Change operation mode, Change flap direction, Change fan speed are restricted by the Permission/Prohibition setting,
restricted items will not be reflected to the favorite setting operation.
Favorite setting operation
You can start an operation with the operation mode, set temp, fan speed, flap direction registered to Favorite set 1 and Favorite set 2.
Settings for the operation mode, set temp, fan speed, flap direction can be registered from Favorite setting on the menu.
Favorite setting operation must be set to the F1 or F2 switch.
Menu
Direction
Cooling
16
:
32 (Mon)
F1: Favorite set 1
F2: Favorite set 2
Timer
In operation for running.
Set temp
1
When you press the F1 ( F2 ) switch, the administrator password input screen is displayed.
After you enter the password, the silent mode control will start.
2
During silent mode control, “Outdoor
unit silent mode control ON” will be
displayed on the message display.
3
When you press the F1 ( F2 ) switch during silent mode control, the display
changes to the administrator password input screen. After you enter the password,
the silent mode control will terminate.
■
Silent mode control will not be disabled even if you press the
Run/Stop
switch.
Terminate the control with the
F1
(
F2
) switch.
■
This operation is to select enable/disable of silent mode control. You cannot start the
operation with the
F1
(
F2
) switches.
Start the operation with the
Run/Stop
switch.
■
When the sub R/C is set, the silent mode control cannot be used.
■
During silent mode control, operation with maximum capacity is not allowed.
Silent mode control
The OU is controlled with priority on quietness. You can start/stop the silent mode control with a single tap of a button. Silent mode control must be set to the F1 or F2
switch. Use the Outdoor unit silent mode timer to set the start and end time.
Menu
Direction
Auto
16
:
00 (Mon)
F1: Silent mode cont
F2: Home leave mode
Timer
Outdoor unit silent mode control ON
Set temp
MEETING1
Room
Select the language
Select the language to be displayed on the R/C.
1
Tap the Menu button on the TOP screen and select Useful functions
⇒
Select the language .
■
Depending on how the Permission/Prohibition setting is set, the administrator password input screen may be displayed.
2
The menu for select the language is displayed.
Select the language to be displayed on the R/C and tap the Set button.
You can select from the following languages:
English/German/French/Spanish/Italian/
Dutch/Turkish/Portugal/Russian/
Polish/Japanese/Chinese
Select the language
Back
Select the language
Set
Next