1  The following should always be observed for safety  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1

2 .  Selecting the installation location   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

3 .  Installation diagram  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

4 .   Refrigerant piping work  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

5 .   Electrical work  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

6 .   Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6

1. The following should always be observed for safety

 Caution:

Could lead to serious injury when operated incorrectly.

• After reading this manual, be sure to keep it together with the instruction 

manual in a handy place on the customer’s site.

 : Indicates a part which must be grounded .

 Warning:

Carefully read the labels affixed to the main unit.

 Warning:

  Do not install the unit by yourself (user).

Improper or incomplete installation could cause fire, electric shock, injury due to 

the unit falling, or water leakage. Consult a qualified installer or the dealer from 

whom you purchased the unit .

  Follow the instructions detailed in the installation manual.

Incomplete installation could cause fire or electric shock, injury due to the unit 

falling, or leakage of water.

  Install the unit securely in a place that can bear the weight of the unit.

If the installation location cannot bear the weight of the unit, the unit could fall 

causing injury.

  Perform electrical work according to the installation manual and be sure to 

use an exclusive circuit. Do not connect other electrical appliances to the 

circuit.

If the capacity of the power circuit is insufficient or there is incomplete electrical 

work, it could result in a fire or an electric shock.

  Ground the unit correctly.

Do not connect the ground wire to a gas pipe, water pipe, lightning rod or tel

-

ephone ground . Defective grounding could cause electric shock .

  Do not damage the wires.

Damaged wires could cause fire.

  Be sure to shut off the main power when setting up the indoor P.C. board or 

wiring.

Failure to do so could cause electric shock .

  Use the specified wires to securely connect the indoor and outdoor units. 

Attach the wires firmly to avoid applying stress to the terminal block.

Improper connection could cause fire.

  Do not install the unit in a place where flammable gas may leak.

If gas leaks and accumulates around the unit, it could cause an explosion.

  Do  not  use  intermediate  connection  of  the  power  cord  or  the  extension 

cord. Do not connect many devices to one AC outlet.

It could cause a fire or an electric shock.

  Use the parts provided or specified parts for the installation work.

The use of defective parts could cause an injury or leakage of water due to a fire, 

an electric shock, the unit falling, etc.

  Securely attach the electrical cover to the indoor unit and the service panel 

to the outdoor unit.

If the electrical cover of the indoor unit and/or the service panel of the outdoor 

unit are not attached securely, dust, water, etc. could collect in the unit and could 

cause a fire or an electric shock.

 When installing or relocating the unit, make sure that no substance other 

than the specified refrigerant (R410A) enters the refrigerant circuit.

Any foreign substances in the refrigerant circuit can cause abnormal pressure 

rise or an explosion.

  Do not discharge the refrigerant into the atmosphere. Check that the refrig-

erant gas does not leak after installation has been completed. If refrigerant 

leaks during installation, ventilate the room.

If refrigerant comes in contact with a fire, harmful gas could be generated.

If refrigerant gas leaks indoors, and comes into contact with the flame of a fan 

heater, space heater, stove, etc., harmful gases will be generated.

  Use appropriate tools and piping materials for installation.

The pressure of R410A is 1 .6 times higher than R22 . Not using the appropriate 

tools and materials, or improper installation could cause the pipes to burst caus

-

ing an injury.

 When pumping down the refrigerant, stop the compressor before discon-

necting the refrigerant pipes.

If the refrigerant pipes are disconnected while the compressor is running and the 

stop valve is open, air could be drawn in and the pressure in the refrigeration cycle 

could become abnormally high, causing the pipes to burst.

  When installing the unit, securely connect the refrigerant pipes before start-

ing the compressor.

If the compressor is started before the refrigerant pipes are connected and the 

stop valve is open, air could be drawn in and the pressure in the refrigeration cycle 

could become abnormally high, causing the pipes to burst.

  Fasten a flare nut with a torque wrench as specified in this manual.

If fastened too tight, a flare nut could break and cause refrigerant leakage.

  Install the unit according to national wiring regulations.

  Do not alter the unit. It may cause fire, electric shock, injury or water leak

-

age.

 Caution:

 Please follow applicable federal, state, or local codes to prevent potential 

leakage/electric shock. Or install a ground fault interrupt for the prevention 

of leakage and electric shock.

 Perform the drainage/piping work securely according to the installation 

manual.

If there is defect in the drainage/piping work, water could drip from the unit, and 

damage household items .

•  Please provide an exclusive circuit for the air conditioner and do not connect 

other electrical appliances to it.

•  Be sure to read “The following should always be observed for safety” before 

installing the air conditioner.

•  Be sure to observe the cautions specified here as they include important 

items related to safety.

•  The indications and meanings are as follows.

 Warning:

Could lead to death or serious injury.

  Do not touch the air inlet or the aluminum fins of the outdoor unit.

This could cause injury.

  Do not install the outdoor unit where small animals may live.

If small animals enter the unit and damage its electrical parts, it could cause a 

malfunction, smoke emission, or fire. Keep the area around the unit clean.

en

1

VG79Y103H01_EN.indd   1

2019/07/18   18:03:42

002

Содержание SUZ-KA09NAHZ

Страница 1: ... que le manuel d installation de l appareil intérieur pour une utilisation sûre et correcte MANUAL DE INSTALACIÓN Para un uso correcto y seguro lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado POUR L INSTALLATEUR PARA EL INSTALADOR FOR INSTALLER Air Conditioners SUZ KA09 KA12 KA15 KA18NAHZ Français Español English VG7...

Страница 2: ...stalling or relocating the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any foreign substances in the refrigerant circuit can cause abnormal pressure rise or an explosion Do not discharge the refrigerant into the atmosphere Check that the refrig erant gas does not leak after installation has been completed If refrigerant leaks during in...

Страница 3: ...e sulfide gas is generated such as a hot spring Where there is high frequency or wireless equipment The outdoor unit produces condensate during the heating operation Select the in stallation place to ensure to prevent the outdoor unit and or the grounds from being wet by drain water or damaged by frozen drain water 2 Selecting the installation location When the piping is to be attached to a wall c...

Страница 4: ... use the insulation of specified thickness table on the above Excessive insulation may cause incorrect installation of the indoor unit and too little insulation may cause condensate to form The unit has flared connections on both indoor and outdoor sides Remove the valve cover from the outdoor unit then connect the pipe Refrigerant pipes are used to connect the indoor and outdoor units Be careful ...

Страница 5: ...urging procedures and leak test 1 Remove service port cap of stop valve on the side of the outdoor unit gas pipe 2 Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outdoor unit 3 Run the vacuum pump 15 minutes or more 4 Check the vacuum with the gauge manifold valve then close it and shut off the vacuum pump 5 Leave as it is for one or two minu...

Страница 6: ...nal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move Warning Be sure to attach the service panel of the indoor unit securely If it is not attached correctly it could result in a fire or an electric shock due to dust water etc Tighten terminal screws securely Wiring should be done so that the power lines are not subject to tension Otherw...

Страница 7: ...ommunication signal line Therefore please turn off the main power supply when servicing And do not touch the S1 S2 S3 terminals when the power is energized If isolator should be used between indoor unit and outdoor unit please use 3 pole type 6 Maintenance 6 1 Gas charge Fig 6 1 1 Connect gas cylinder to the service port of stop valve 3 way 2 Execute air purge of the pipe or hose coming from refri...

Страница 8: ...gération La présence d une substance étrangère dans le circuit de réfrigération peut pro voquer une augmentation anormale de la pression voire une explosion Ne libérez pas le réfrigérant dans l atmosphère Vérifiez l absence de fuites de gaz réfrigérant une fois l installation terminée En cas de fuite de réfrigé rant pendant l installation aérez la pièce Si le réfrigérant entre en contact avec un f...

Страница 9: ...ermale En présence d équipements haute fréquence ou sans fil L unité extérieure produit de la condensation lors du mode de chauffage Choisir l endroit où le climatiseur sera monté de façon à éviter à l unité extérieure et ou aux sols d être mouillés par les condensats ou endommagés par le gel des condensats 2 Choisir l emplacement de l installation Lorsque les tuyaux seront attachés à un mur conte...

Страница 10: ...ntion Utilisez toujours un matériau d isolation de l épaisseur spécifiée tableau à droite Une isolation trop épaisse peut être à l origine d une installation incorrecte de l unité interne une isolation trop fine peut provoquer la formation de condensation L unité comporte des raccordements évasés sur les faces intérieure et extérieure Retirez le couvercle de vanne de l unité externe et raccordez l...

Страница 11: ...t test de contrôle des fuites 1 Retirez le bouchon de l ouverture de service du robinet d arrêt du côté du tuyau de gaz de l unité externe 2 Raccordez la vanne du collecteur à jauge et la pompe à vide à l ouverture de service du robinet d arrêt du côté du tuyau de gaz de l unité externe 3 Faites fonctionner la pompe à vide pendant 15 minutes minimum 4 Contrôlez la dépression ainsi obtenue avec la ...

Страница 12: ...eil intérieur à la boîte de sorties Utiliser le même bloc de sorties et la même polarité que pour l unité intérieure Pour pouvoir effectuer des révisions dans le futur laisser un peu de jeu dans le câble de connexion Les deux extrémités du câble de connexion rallonge doivent être dénudées Lorsque le câble est trop long ou lorsqu il est relié à partir du milieu dénuder le câble d alimentation en re...

Страница 13: ...ls d alimentation en cuivre 3 Utiliser des fils d une intensité nominale de 600V ou plus pour les câbles d alimentation et les câbles de raccordement de l appareil intérieur l appareil extérieur 4 Installer un câble de terre plus long que les autres câbles 6 1 Charge de Gaz Fig 6 1 1 Raccorder le tuyau de gaz au port de service de la vanne d arrêt à 3 voies 2 Purger l air du tuyau raccordé au tuya...

Страница 14: ...elevación anómala de la presión o una explosión No descargue el refrigerante en el ambiente Una vez acabada la instala ción compruebe que no haya fugas de gas refrigerante Si se producen fugas de refrigerante durante la instalación ventile la habitación Si el refrigerante entra en contacto con una llama podría generarse gas nocivo Si se produjeran pérdidas de gas refrigerante en un interior y entr...

Страница 15: ...onas de baños termales Donde haya algún equipo inalámbrico o de alta frecuencia La unidad exterior provoca condensación durante la función de calefacción Selec cione un lugar para la instalación en el que la unidad exterior y las tomas de tierra no se humedezcan con agua de drenaje ni se dañen debido a la congelación de este agua de drenaje 2 Selección del lugar de instalación Cuando tenga que ins...

Страница 16: ...de grosor especificado tabla de la derecha El uso excesivo de aislante puede causar una instalación incorrecta de la unidad interior y el uso de una cantidad insuficiente de aislante puede provocar la condensación Las unidad tiene conexiones abocinadas en los lados interior y exterior Retire la tapa de la válvula de la unidad exterior y a continuación conecte la tubería Las tuberías de refrigerant...

Страница 17: ...nción situada en el lado de la tubería de gas de la unidad exterior 2 Conecte la válvula colectora de manómetro y la bomba de vacío al puerto de servicio de la válvula de retención en el lado de la tubería del gas de la unidad exterior 3 Ponga en funcionamiento la bomba de vacío durante 15 minutos o más 4 Compruebe el vacío con la válvula colectora de manómetro cierre luego esta válvula y detenga ...

Страница 18: ...lojen Tras apretarlos tire ligeramente de los cables para confirmar que no se muevan Atención Asegúrese de fijar firmemente el panel de servicio de la unidad exterior Si no se monta correctamente podría producirse un incendio o un electro choque a causa del polvo el agua etc Apriete firmemente los tornillos de cada terminal Realice el cableado de modo que los cables de alimentación no estén en ten...

Страница 19: ...e 3 Utilice cables con un régimen nominal de 600 V o superior para los cables de la fuente de alimentación y los cables de conexión de las unidades inte rior exterior 4 Instale un cable de toma de tierra más largo que el resto de los cables 6 1 Carga de gas Fig 6 1 1 Conecte el cilindro de gas a la abertura de servicio de la válvula de parada de 3 vías 2 Purgue el aire del tubo o conducto proceden...

Страница 20: ...t address telephone number on this manual before handing it to the customer VG79Y103H01 Printed in Thailand HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VG79Y103H01_cover4 indd 20 2019 06 28 18 07 18 020 ...