3. Installation diagram

2.1. Outdoor unit

•  Where it is not overly exposed to strong winds.

•  Where airflow is good and dustless.

•  Where neighbors are not annoyed by operation sound or hot air .

•  Where rigid wall or support is available to prevent the increase of operation sound 

or vibration .

•  Where there is no risk of combustible gas leakage .

•  If installing the unit in a location high above the ground, be sure to secure the unit 

legs .

•  Where it is at least 10 ft . (3 m) away from the antenna of TV set or radio . Opera-

tion of the air conditioner may interfere with radio or TV reception in areas where 

reception is weak. An amplifier may be required for the affected device.

•  Install the unit horizontally .

•  Please install it in an area not affected by snowfall or blowing snow . In areas with 

heavy snow, please install a canopy, a pedestal and/or baffle boards.

Note: 

•  It is advisable to make a piping loop near outdoor unit so as to reduce vibration .

•  For increased efficiency, install the outdoor unit in a location where continuous 

direct sunlight or excessive water can be avoided as much as possible.

 Caution:

When operating the air conditioner in low outside temperature, be sure to follow the 

instructions described below .

•  Never install the outdoor unit in a place where its air inlet/outlet side may be ex

-

posed directly to wind .

•  To prevent exposure to wind, install the outdoor unit with its air inlet side facing the 

wall and a baffle board on the air outlet side.

Avoid the following places for installation where air conditioner trouble is liable to 

occur .

•  Where flammable gas could leak

•  Where there is an excessive amount of machine oil in the air.

•  Salty places such as the seaside .

•  Where sulfide gas is generated such as a hot spring.

•  Where there is high-frequency or wireless equipment.

The outdoor unit produces condensate during the heating operation . Select the in-

stallation place to ensure to prevent the outdoor unit and/or the grounds from being 

wet by drain water or damaged by frozen drain water .

2. Selecting the installation location

When the piping is to be attached to a wall containing metals (tin plated) or metal netting, use a chemically treated wooden piece 25/32 in. (20 mm) or thicker between the wall 

and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping .

Units should be installed by licensed contractor accordingly to local code requirement.

Note:

When operating the air conditioner in low outside temperature, be sure to follow the instructions described below.

•  Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to wind.

•  To prevent exposure to wind, install the outdoor unit with its air inlet side facing the wall.

•  To prevent exposure to wind, it is recommended to install a baffle board on the air outlet side of the outdoor unit.

Drain piping for outdoor unit

Install the unit horizontally .

Do not use drain socket in cold regions . Drain may freeze and make the fan stop .

The outdoor unit produces condensate during the heating operation . Select the installation place to ensure to prevent the outdoor unit and/or the grounds from being wet 

by drain water or damaged by frozen drain water .

SUZ-KA09, KA12, KA15, KA18NAHZ

4 in . (100

 mm) 

or more

20 in . (500 mm) 

or more

20 in .

 (500

 mm) 

or more

4 in . (100

 mm) 

or more

14 in . (350

 mm) 

or more

Unit: inch

Unit: mm

33-1/16

14-3/4~14-5/8

19-11/16

Air inlet

6-7/8

15-3/8

13

Air outlet

2-3/8 x 13/16 slot

1-18/32

Air inlet

40

840

175

500

Air inlet

390

330

349~371

Air outlet

2-10 x 21 slot

Air inlet

en

2

VG79Y103H01_EN.indd   2

2019/07/18   18:03:42

003

Содержание SUZ-KA09NAHZ

Страница 1: ... que le manuel d installation de l appareil intérieur pour une utilisation sûre et correcte MANUAL DE INSTALACIÓN Para un uso correcto y seguro lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado POUR L INSTALLATEUR PARA EL INSTALADOR FOR INSTALLER Air Conditioners SUZ KA09 KA12 KA15 KA18NAHZ Français Español English VG7...

Страница 2: ...stalling or relocating the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any foreign substances in the refrigerant circuit can cause abnormal pressure rise or an explosion Do not discharge the refrigerant into the atmosphere Check that the refrig erant gas does not leak after installation has been completed If refrigerant leaks during in...

Страница 3: ...e sulfide gas is generated such as a hot spring Where there is high frequency or wireless equipment The outdoor unit produces condensate during the heating operation Select the in stallation place to ensure to prevent the outdoor unit and or the grounds from being wet by drain water or damaged by frozen drain water 2 Selecting the installation location When the piping is to be attached to a wall c...

Страница 4: ... use the insulation of specified thickness table on the above Excessive insulation may cause incorrect installation of the indoor unit and too little insulation may cause condensate to form The unit has flared connections on both indoor and outdoor sides Remove the valve cover from the outdoor unit then connect the pipe Refrigerant pipes are used to connect the indoor and outdoor units Be careful ...

Страница 5: ...urging procedures and leak test 1 Remove service port cap of stop valve on the side of the outdoor unit gas pipe 2 Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outdoor unit 3 Run the vacuum pump 15 minutes or more 4 Check the vacuum with the gauge manifold valve then close it and shut off the vacuum pump 5 Leave as it is for one or two minu...

Страница 6: ...nal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move Warning Be sure to attach the service panel of the indoor unit securely If it is not attached correctly it could result in a fire or an electric shock due to dust water etc Tighten terminal screws securely Wiring should be done so that the power lines are not subject to tension Otherw...

Страница 7: ...ommunication signal line Therefore please turn off the main power supply when servicing And do not touch the S1 S2 S3 terminals when the power is energized If isolator should be used between indoor unit and outdoor unit please use 3 pole type 6 Maintenance 6 1 Gas charge Fig 6 1 1 Connect gas cylinder to the service port of stop valve 3 way 2 Execute air purge of the pipe or hose coming from refri...

Страница 8: ...gération La présence d une substance étrangère dans le circuit de réfrigération peut pro voquer une augmentation anormale de la pression voire une explosion Ne libérez pas le réfrigérant dans l atmosphère Vérifiez l absence de fuites de gaz réfrigérant une fois l installation terminée En cas de fuite de réfrigé rant pendant l installation aérez la pièce Si le réfrigérant entre en contact avec un f...

Страница 9: ...ermale En présence d équipements haute fréquence ou sans fil L unité extérieure produit de la condensation lors du mode de chauffage Choisir l endroit où le climatiseur sera monté de façon à éviter à l unité extérieure et ou aux sols d être mouillés par les condensats ou endommagés par le gel des condensats 2 Choisir l emplacement de l installation Lorsque les tuyaux seront attachés à un mur conte...

Страница 10: ...ntion Utilisez toujours un matériau d isolation de l épaisseur spécifiée tableau à droite Une isolation trop épaisse peut être à l origine d une installation incorrecte de l unité interne une isolation trop fine peut provoquer la formation de condensation L unité comporte des raccordements évasés sur les faces intérieure et extérieure Retirez le couvercle de vanne de l unité externe et raccordez l...

Страница 11: ...t test de contrôle des fuites 1 Retirez le bouchon de l ouverture de service du robinet d arrêt du côté du tuyau de gaz de l unité externe 2 Raccordez la vanne du collecteur à jauge et la pompe à vide à l ouverture de service du robinet d arrêt du côté du tuyau de gaz de l unité externe 3 Faites fonctionner la pompe à vide pendant 15 minutes minimum 4 Contrôlez la dépression ainsi obtenue avec la ...

Страница 12: ...eil intérieur à la boîte de sorties Utiliser le même bloc de sorties et la même polarité que pour l unité intérieure Pour pouvoir effectuer des révisions dans le futur laisser un peu de jeu dans le câble de connexion Les deux extrémités du câble de connexion rallonge doivent être dénudées Lorsque le câble est trop long ou lorsqu il est relié à partir du milieu dénuder le câble d alimentation en re...

Страница 13: ...ls d alimentation en cuivre 3 Utiliser des fils d une intensité nominale de 600V ou plus pour les câbles d alimentation et les câbles de raccordement de l appareil intérieur l appareil extérieur 4 Installer un câble de terre plus long que les autres câbles 6 1 Charge de Gaz Fig 6 1 1 Raccorder le tuyau de gaz au port de service de la vanne d arrêt à 3 voies 2 Purger l air du tuyau raccordé au tuya...

Страница 14: ...elevación anómala de la presión o una explosión No descargue el refrigerante en el ambiente Una vez acabada la instala ción compruebe que no haya fugas de gas refrigerante Si se producen fugas de refrigerante durante la instalación ventile la habitación Si el refrigerante entra en contacto con una llama podría generarse gas nocivo Si se produjeran pérdidas de gas refrigerante en un interior y entr...

Страница 15: ...onas de baños termales Donde haya algún equipo inalámbrico o de alta frecuencia La unidad exterior provoca condensación durante la función de calefacción Selec cione un lugar para la instalación en el que la unidad exterior y las tomas de tierra no se humedezcan con agua de drenaje ni se dañen debido a la congelación de este agua de drenaje 2 Selección del lugar de instalación Cuando tenga que ins...

Страница 16: ...de grosor especificado tabla de la derecha El uso excesivo de aislante puede causar una instalación incorrecta de la unidad interior y el uso de una cantidad insuficiente de aislante puede provocar la condensación Las unidad tiene conexiones abocinadas en los lados interior y exterior Retire la tapa de la válvula de la unidad exterior y a continuación conecte la tubería Las tuberías de refrigerant...

Страница 17: ...nción situada en el lado de la tubería de gas de la unidad exterior 2 Conecte la válvula colectora de manómetro y la bomba de vacío al puerto de servicio de la válvula de retención en el lado de la tubería del gas de la unidad exterior 3 Ponga en funcionamiento la bomba de vacío durante 15 minutos o más 4 Compruebe el vacío con la válvula colectora de manómetro cierre luego esta válvula y detenga ...

Страница 18: ...lojen Tras apretarlos tire ligeramente de los cables para confirmar que no se muevan Atención Asegúrese de fijar firmemente el panel de servicio de la unidad exterior Si no se monta correctamente podría producirse un incendio o un electro choque a causa del polvo el agua etc Apriete firmemente los tornillos de cada terminal Realice el cableado de modo que los cables de alimentación no estén en ten...

Страница 19: ...e 3 Utilice cables con un régimen nominal de 600 V o superior para los cables de la fuente de alimentación y los cables de conexión de las unidades inte rior exterior 4 Instale un cable de toma de tierra más largo que el resto de los cables 6 1 Carga de gas Fig 6 1 1 Conecte el cilindro de gas a la abertura de servicio de la válvula de parada de 3 vías 2 Purgue el aire del tubo o conducto proceden...

Страница 20: ...t address telephone number on this manual before handing it to the customer VG79Y103H01 Printed in Thailand HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VG79Y103H01_cover4 indd 20 2019 06 28 18 07 18 020 ...

Отзывы: