11
OCH562D
PUHZ-W112VHA PUHZ-W112VHAR2
PUHZ-W112VHA-BS PUHZ-W112VHAR2-BS
PUHZ-W112VHAR1 PUHZ-W112VHAR3
PUHZ-W112VHAR1-BS PUHZ-W112VHAR3-BS
Rear
Air
Intake
2-12×36 oval holes (Foundation Bolt M10)
2-U Shaped notched holes (Foundation Bolt M10)
Installation Feet
Side Air
Intake
Air Discharge
30
330
210
600
210
28
53
370
19
417
Handle for moving
Service panel
Terminal connections Left
···
Power supply wiring
Right
···
Controller wiring
Earth terminal
Handle for moving
Handle for moving
1020
322
1350
1079
371
23
635
Power supply wiring hole (2-
{
27Knock Out)
Front cover
see Detail
Air Intake
40
74
34
Handle for moving
Rear Air
Intake
Handle for moving
W
ater OUT
W
ater IN
59
Handle for moving
Side Air
Intake
Detail Scale 1:6
ISO 228-1 G1 B
466
74
24
Drain hole (5-
{
33)
219
81
30
256
133
133
133
FOUNDA
TION
<Foundation bolt height>
Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally
.)
30
Service space
Dimensions of space needed for service access are shown in the below diagram.
500
500
FREE
Over 300mm
Over 10mm
The diagram below shows a basic example. Explanation of particular details are given in the installation manuals etc.
Over 10mm
1 FREE SP
ACE (Around the unit)
2 SER
VICE SP
ACE
3 FOUNDA
TION BOL
TS
Less than
Over
Over
Over 500mm
Unit: mm
OUTLINES AND DIMENSIONS
4