Table 2-1-4 shows the typical control part characteristics. (T
j
= 25°C, unless otherwise noted)
Table 2-1-4. Typical control part characteristics of PSS25MC1FT(25A/1200V, CIB type)
CONTROL (PROTECTION) PART
Symbol
Parameter
Condition
Limits
Unit
Min.
Typ.
Max.
I
D
Circuit current
Total of V
P1
-V
NC
, V
N1
-V
NC
V
D
=15V, V
IN
=0V
-
-
5.70
mA
V
D
=15V, V
IN
=5V
-
-
5.70
I
DB
Each part of V
UFB
-V
UFS
,
V
VFB
-V
VFS
, V
WFB
-V
WFS
V
D
=V
DB
=15V, V
IN
=0V
-
-
0.55
V
D
=V
DB
=15V, V
IN
=5V
-
-
0.55
V
SC(ref)
Short circuit trip level
V
D
= 15V
(Note 4)
0.455
0.480
0.505
V
UV
DBt
Control supply under-voltage
protection(UV) for P-side of
inverter part
Trip level
10.0
-
12.0
V
UV
DBr
Reset level
10.5
-
12.5
V
UV
Dt
Control supply under-voltage
protection(UV) for N-side of
inverter part and brake part
Trip level
10.3
-
12.5
V
UV
Dr
Reset level
10.8
-
13.0
V
V
OT
Temperature Output
Pull down R=5.1k
Ω
(Note 5)
LVIC
Temperature=100
°
C
2.89
3.02
3.14
V
V
FOH
Fault output voltage
V
SC
= 0V, F
O
terminal pulled up to 5V by 10k
Ω
4.9
-
-
V
V
FOL
V
SC
= 1V, I
FO
= 1mA
-
-
0.95
V
t
FO
Fault output pulse width
In case of C
Fo
=22nF
(Note 6,7)
1.6
2.4
-
ms
I
IN
Input current
V
IN
= 5V
0.70
1.00
1.50
mA
V
th(on)
ON threshold voltage
Applied between U
P
,V
P
,W
P
,U
N
, V
N
, W
N
, AIN-V
NC
-
-
3.5
V
V
th(off)
OFF threshold voltage
0.8
-
-
V
F
Bootstrap Di forward voltage
I
F
=10mA including voltage drop by limiting resistor
0.9
1.3
V
R
Built-in limiting resistance
Included in bootstrap Di
16
20
24
Ω
Note 4 : SC protection works only for N-side IGBT in inverter part. Please select the external shunt resistance such that
the SC trip-level is less than 1.7 times of the current rating.
5 : DIPIPM don't shutdown IGBTs and output fault signal automatically when temperature rises excessively. When
temperature exceeds the protective level that user defined, controller (MCU) should stop the DIPIPM.
Temperature of LVIC vs. VOT output characteristics is described in Section 2.2.3.
6 : Fault signal Fo outputs when SC or UV protection works for N-side IGBT in inverter part. The fault output
pulse-width t
FO
is depended on the capacitance value of C
FO
(C
FO
= t
FO
×
9.1
×
10
-6
[F]).
7 : UV protection also works for P-side IGBT in inverter part or brake part without fault signal Fo.