49
F Check of compressor operation time
MUZ-A09/12/15/17 MUY-A15/17
G Check of outdoor thermistors
●
Connect the compressor and activate the inverter. Then measure
the time until the inverter stops due to over current.
<<Operation method>>
Start heating or cooling operation by pressing EMERGENCY
OPERATION switch on the indoor unit.
(TEST RUN OPERATION: Refer to 7-7.)
<<Measurement>>
Measure the time from the start of outdoor fan running to the stop
of compressor due to overcurrent.
MUZ-A09/12/15/17 MUY-A15/17
Thermistor
Symbol
Connector, Pin No.
Board
Defrost
RT61 Between CN641 pin 1 and pin 2
Inverter P.C. board
Discharge temperature
RT62 Between CN641 pin 3 and pin 4
Fin temperature
RT64 Between CN642 pin 1 and pin 2
Ambient temperature
RT65 Between CN643 pin 1 and pin 2
MUZ-A24 MUY-A24 MUZ-GA24 MUY-GA24
Thermistor
Symbol
Connector, Pin No.
Board
Defrost
RT61 Between CN661 pin 1 and pin 2
Outdoor electronic control P.C. board
Discharge temperature
RT62 Between CN661 pin 3 and pin 4
Outdoor heat exchanger temperature RT68 Between CN661 pin 7 and pin 8
Ambient temperature
RT65 Between CN663 pin 1 and pin 2
Fin temperature
RT64 Between CN3 pin 1 and pin 2
Outdoor power board
Replace the thermistor except RT64.
When RT64 is abnormal, replace the inverter P.C.
board or the outdoor power board.
Replace the inverter P.C. board
or the outdoor power board.
No
No
Is the thermistor normal? (Refer to 10-6.1.
or 10-6.3.)
Reconnect the connector of thermistor.
Turn ON the power supply and press EMERGENCY OPERATION switch.
Does the unit operate for 10 minutes or more
without showing thermistor abnormality?
OK.
(Cause is poor contact.)
Yes
Yes
Disconnect the connector of thermistor in the outdoor P.C. board (see
below table), and measure the resistance of thermistor.
Compressor starts
Abnormal
(IPM failure)
(Compressor winding short)
Abnormal
(Compressor lock out)
(Starting defect)
Abnormal
(Poor contact,)
(Outdoor P.C. board defect)
(Disconnected connector)
Abnormal
(Refrigerant circuit defect)
(Closed valve)
Normal
0 second
1 second
2 seconds
10 seconds
10 minutes
<<Judgement>>
Содержание Mr.Slim MUZ-A17NA
Страница 12: ...12 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA 5 WIRING DIAGRAM ...
Страница 13: ...13 MUY A15NA MUY A17NA ...
Страница 14: ...14 MUZ A24NA MUZ A24NA U1 ...
Страница 15: ...15 MUZ A24NA 1 MUZ A24NA U2 ...
Страница 16: ...16 MUY A24NA ...
Страница 17: ...17 MUY A24NA 1 ...
Страница 18: ...18 MUZ GA24NA ...
Страница 19: ...19 MUY GA24NA ...
Страница 74: ...74 8 1 4 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA MUY A15NA MUY A17NA 2 OUTDOOR UNIT ELECTRICAL PARTS 2 3 5 6 7 ...
Страница 80: ...80 8 1 4 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA MUY A15NA MUY A17NA 2 OUTDOOR UNIT ELECTRICAL PARTS 2 3 5 6 7 ...