MUY-A24NA
MUZ-A24NA
MUZ-A24NA
Capacity correction factors
Input correction factors
Input correction factors
Capacity correction factors
Correction of Cooling capacity
The operational frequency of compressor
Correction of Cooling total input
The operational frequency of compressor
Correction of Heating total input
The operational frequency of compressor
Correction of Heating capacity
Correction of Heating capacity
The operational frequency of compressor
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
MUY-GA24NA
MUZ-GA24NA
MUZ-GA24NA
Capacity correction factors
Input correction factors
Input correction factors
Capacity correction factors
Correction of Cooling capacity
The operational frequency of compressor
Correction of Cooling total input
The operational frequency of compressor
Correction of Heating total input
The operational frequency of compressor
The operational frequency of compressor
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
Capacity correction factors
Input correction factors
Input correction factors
Capacity correction factors
Correction of Cooling capacity
The operational frequency of compressor
Correction of Cooling total input
The operational frequency of compressor
Correction of Heating total input
The operational frequency of compressor
Correction of Heating capacity
The operational frequency of compressor
MUY-A17NA
MUZ-A17NA
MUZ-A17NA
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
0
50
100
150
0.0
0.5
1.0
1.5
(Hz)
7-6. TEST RUN OPERATION (How to operate fixed-frequency operation)
1. Press EMERGENCY OPERATION switch to COOL or HEAT mode (COOL: Press once, HEAT: Press twice).
2. Test run operation starts and continues to operate for 30 minutes.
3. Compressor operates at rated frequency in COOL mode or 58 Hz in HEAT mode.
4. Indoor fan operates at High speed.
5. After 30 minutes, test run operation finishes and EMERGENCY OPERATION starts (operation frequency of compressor
varies).
6. To cancel test run operation (EMERGENCY OPERATION), press EMERGENCY OPERATION switch or any button on
remote controller.
Содержание Mr.Slim MUZ-A17NA
Страница 12: ...12 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA 5 WIRING DIAGRAM ...
Страница 13: ...13 MUY A15NA MUY A17NA ...
Страница 14: ...14 MUZ A24NA MUZ A24NA U1 ...
Страница 15: ...15 MUZ A24NA 1 MUZ A24NA U2 ...
Страница 16: ...16 MUY A24NA ...
Страница 17: ...17 MUY A24NA 1 ...
Страница 18: ...18 MUZ GA24NA ...
Страница 19: ...19 MUY GA24NA ...
Страница 74: ...74 8 1 4 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA MUY A15NA MUY A17NA 2 OUTDOOR UNIT ELECTRICAL PARTS 2 3 5 6 7 ...
Страница 80: ...80 8 1 4 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA MUY A15NA MUY A17NA 2 OUTDOOR UNIT ELECTRICAL PARTS 2 3 5 6 7 ...