4
INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT
• This room air conditioner adopts HFC refrigerant (R410A) which never destroys the ozone layer.
• Pay particular attention to the following points, though the basic installation procedure is same as that for R22 air condition-
ers.
As R410A has working pressure approximate 1.6 times as high as that of R22, some special tools and piping parts/materials
are required. Refer to the table below.
Take sufficient care not to allow water and other contaminations to enter the R410A refrigerant during storage and installa-
tion, since it is more susceptible to contaminations than R22.
For refrigerant piping, use clean, pressure-proof parts/materials specifically designed for R410A. (Refer to 2. Refrigerant pip-
ing.)
Composition change may occur in R410A since it is a mixed refrigerant. When charging, charge liquid refrigerant to prevent
composition change.
New refrigerant
Previous refrigerant
Refrigerant
Refrigerant R410A
R22
Composition (Ratio)
HFC-32: HFC-125 (50%: 50%)
R22 (100%)
Refrigerant handling
Pseudo-azeotropic refrigerant
Single refrigerant
Chlorine Not
included
Included
Safety group (ASHRAE)
A1 / A1
A1
Molecular weight
72.6
86.5
Boiling point (°F)
-60.5
-41.4
Steam pressure [77°F] (PSIG)
225.82
136.34
Saturated steam density [77°F] (lb./ft.
3
) 3.995
2.772
Combustibility
Non combustible
Non combustible
ODP 1 0
0.055
GWP 2 1730
1700
Refrigerant charge method
From liquid phase in cylinder
Gas phase
Additional charge on leakage
Possible
Possible
Refrigeration oil
Kind
Incompatible oil
Compatible oil
Color None
Light
yellow
Smell None
None
1: Ozone Depletion Potential: based on CFC-11
2: Global Warming Potential: based on CO2
New Specification
Current Specification
Compressor
The incompatible refrigeration oil easily separates from
refrigerant and is in the upper layer inside the suction
muf
fl
er.
Raising position of the oil back hole enables to back the
refrigeration oil of the upper layer to flow back to the
compressor.
Since refrigerant and refrigeration oil are compatible with
each other, refrigeration oil goes back to the compressor
through the lower position oil back hole.
Compressor
Suction muffler
Oil back hole
refrigeration oil
Refrigerant
Compressor
Suction muffler
Oil back hole
Refrigeration oil /Refrigerant
Содержание Mr.Slim MUZ-A17NA
Страница 12: ...12 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA 5 WIRING DIAGRAM ...
Страница 13: ...13 MUY A15NA MUY A17NA ...
Страница 14: ...14 MUZ A24NA MUZ A24NA U1 ...
Страница 15: ...15 MUZ A24NA 1 MUZ A24NA U2 ...
Страница 16: ...16 MUY A24NA ...
Страница 17: ...17 MUY A24NA 1 ...
Страница 18: ...18 MUZ GA24NA ...
Страница 19: ...19 MUY GA24NA ...
Страница 74: ...74 8 1 4 MUZ A09NA MUZ A12NA MUZ A15NA MUZ A17NA MUY A15NA MUY A17NA 2 OUTDOOR UNIT ELECTRICAL PARTS 2 3 5 6 7 ...