E
To turn ON
¡
Power lamp lights.
To start dehumidifying, select the desired
mode.
To turn OFF
¡
Power lamp turns off.
Close the louvre manually.
<If drying inside is set>
Drying inside will operate. Set the louvre
upright.
11
9
Operating
Bef
ore using the unit
Carrying the
Unit
Turning the Unit
ON and OFF
∞
Do not carry the unit on its side
as this may
cause malfunctions.
∞
Do not let the power cord drag, as this may
damage the cord.
Note
Before moving the unit, first make sure to
remove water from the water tank and
close the louvre.
The dehumidifier remembers the
operating mode. Even if the plug is
disconnected or the power turned off, the
unit restarts at the previous setting.
Pull the handle out,
and grasp with a firm
grip
Press
The compressor does not activate for 3 minutes
when the unit is turned ON immediately after
turning it OFF or plugging it into the power
socket. (In order to protect the compressor.)
When dehumidifying begins, the operational
noise increases.
Inf
ormation
Press
∞
If the room temperature falls below 15°C,
defrosting mode is activated once every 40
minutes (for about 5 minutes) causing water to
drain to the tank.
∞
The unit can operate in a room temperature range
of 1-35°C.
However, if the room temperature exceeds 35°C,
the unit may operate in blower mode or increase
the airflow. This is because the temperature within
the unit rises causing the protection mechanism to
operate. In order to lower the temperature within the
unit, when using the louvre in the vertical position.
• If the temperature is below 1°C, the extracted
water is close to freezing disabling the
dehumidifier, and only the blower is operational.
7